MAINTENANCE

To ensure continuing high performance, and to minimize the
possibility of premature equipment failure, periodic maintenance
must be performed on this equipment. This heat pump unit should
be inspected at least once each year by a qualified service person.
To troubleshoot unit, refer to Table 11.
NOTE TO EQUIPMENT OWNER: Consult your local dealer
about the availability of a maintenance contract.

WARNING: The ability to properly perform mainte-
nance on this equipment requires certain expertise, me-
chanical skills, tools and equipment. If you do not possess
these, do not attempt to perform any maintenance on this
equipment, other than those procedures recommended in
the User’s Manual. FAILURE TO HEED THIS WARN-
ING COULD RESULT IN SERIOUS INJURY OR
DEATH AND POSSIBLE DAMAGE TO THIS EQUIP-
MENT.

WARNING: Failure to follow these warnings could
result in serious injury or death:
1. Turn off electrical power to the unit and install lockout

tag before performing any maintenance or service on
this unit.

2. Use extreme caution when removing panels and parts.

As with any mechanical equipment, personal injury
can result from sharp edges.

3. Never place anything combustible either on, or in

contact with, the unit.

CAUTION: Errors made when reconnecting wires may
cause improper and dangerous operation. Label all wires
prior to disconnecting when servicing.

The minimum maintenance requirements for this equipment are as
follows:

1. Inspect air filter(s) each month. Clean or replace when

necessary.

2. Inspect indoor coil, drain pan, and condensate drain each

cooling season for cleanliness. Clean when necessary.

3. Inspect blower motor and wheel for cleanliness each

cooling season. Clean when necessary.

4. Check electrical connections for tightness and controls for

proper operation each cooling season. Service when neces-
sary.

5. Ensure wires are not contacting refrigerant tubing or sharp

sheet metal edges.

I.

AIR FILTER

IMPORTANT: Never operate the unit without a suitable air filter
in the return-air duct system. Always replace the filter with the
same dimensional size and type as originally installed (See Tables
1 and 2 for recommended filter sizes.)
Inspect air filter(s) at least once each month and replace
(throwaway-type) or clean (cleanable-type) at least twice during
each cooling season or whenever the filter becomes clogged with
dust and lint.
II.

INDOOR BLOWER AND MOTOR

NOTE: All motors are prelubricated. Do not attempt to lubricate
these motors.

Fig. 23—601A Balance Point Worksheet

C00094rev2

Balance Point Worksheet

0

10

20

30

40

50

60

70

-10

0

10

17

20

30

40

47

50

60

Outdoor Air Temp (Deg F)

030
036
042
048
060

Based on Indoor Entering Air of 70 F and Rated CFM

Building Heat Loss

, 1000BTUH

Unit Integrated Heating Capacity (x1000BTUH)

—18—