81823

Push T-handle in fully and
manually move platform in
and out to engage platform
lock before driving vehicle.
Failure to lock platform may
result in unintended platform
deployment. Unintended
platform deployment may
result in serious bodily injury
and/or property damage.

Do not remove!

TO

LOCK

TU

RN

Manual Operating Instructions

A

Hand

Pump

Hand Pump Handle

Release Valve

maximum

30 inch lbs

minimum

15 inch lbs

seats

(stops)

O

P

E

N

C

L

O

S

E

approximate 1/16" intervals

Valve Tightening Specification:
Once valve seats (stops), tighten
15 to 30 inch pounds as shown.

Figure 1

Figure 2

WA

RN

ING

81823

Push T-handle in fully and
manually move platform in
and out to engage platform
lock before driving vehicle.
Failure to lock platform may
result in unintended platform
deployment. Unintended
platform deployment may
result in serious bodily injury
and/or property damage.

Do not remove!

TO

LO

CK

TURN

Open

(Down)

Close

(Up/Stop)

B

C

b

a

a

b

Hand Pump Handle

To Manually Lower Platform
To Ground Level:

Note: Disregard procedures for
manually moving the platform in or
out if not applicable.

When lowering platform from
floor level:

1. a. Pull “T” handle release cable

outward and b. turn “T” handle
to lock platform into the re-
leased position (see Figure 1).

2. Pull platform out fully (until it

stops), if applicable.

3. Reengage the release cable

mechanism by a. turning the “T”
handle and b. pushing the “T”
handle in fully (see Figure 2).

Note: Grasp the outer roll stop
and move the platform in and
out until the platform locks.
You will feel the release mecha-
nism engage. Read Platform
Carriage Assembly Drive
Chain Reengagement Proce-
dure
section on page 16!

4. Place slotted end of pump

handle onto hand pump down
(release) valve and turn coun-
terclockwise
(open 1/2 turn
only
) to lower platform. See
Photo B.

5. Turn hand pump down (release)

valve clockwise (close) before
performing any other lift func-
tions. See Photo B.

Note: Close hand pump
release valve securely before
operating lift. The lift will not
operate properly if the valve is
not in its fully clockwise posi-
tion.

Release