CLOSE CLEARANCE INSTALLATIONS (in inches)

Close clearance installation is possible by using the following brands of black, double-wall chimney pipe. (See
Figure 4 and Figure 5 for clearances.)

1. Simpson Dura-Vent double wall chimney connector “Type DVL” and 8" Simpson Dura-Vent 2100

o

HT

“Type DP” chimney

2. 8" Security Type DL double wall connector and 8" Security Type “ASHT” High Temp Chimney.
3. 8" Selkirk Metal Bestos Model “DS” double wall connector-8" Selkirk Metal Bestos Model SSII type HT

Chimney System.

4. 8" Metal Fab type “DW” double wall connector - 8" Metal Fab 2100

o

HT chimney.

5. 8"

Air

Jet















FIGURE 4

FIGURE 5

TOOLS FOR INSTALLATION


Drop Cloth
Electric Drill with 3/32" drill bit
5/16" combination wrench
5/16" magnetic socket chuck adapter, 5/16"
wrench (box or socket) or adjustable wrench
Pencil Socket Set
Level Tape Measure
Screw Driver

Wall Exit into Metal Tee-Box (Using
Single Wall Pipe)


1. Mark the plumb line on the wall directly

behind the center of the heater. (See Figure
6.)

NOTE: When using #24 ga. min. blued or black
steel pipe, maintain 18" between pipe and
ceiling.
2. Place the vertical portion of the heater pipe

and the elbow in position and project a point
onto the plumb line level with the center of
the elbow.

FIGURE 6

1/4” Rise Per. FT.