Masonry insert installation, Installation options – New Buck Corporation 91 User Manual

Page 8

Advertising
background image

SECTION II

MASONRY INSERT INSTALLATION

INSTALLATION OPTIONS

This unit (appliance) may be installed into an all masonry fireplace, built in accordance with the Uniform Building Code
and the National Fire Protection Association (NFPA 211).
NOTE: Check with local building officials for any permits required for installation of this stove and notify your insurance
company before proceeding with installation.

A. At a minimum, a starter pipe reaching from the stove flue exit to the base of the existing code approved masonry

chimney (flue-liner) and an airtight face seal.

B. Direct connection: In accordance with NFPA-211-9-4.5, Connection to Masonry Fireplaces. A solid fuel-burning

appliance such as a stove or insert shall be permitted to use a masonry fireplace flue where the following conditions
are met:

Exception: Listed fireplace accessories shall be permitted to use a masonry fireplace flue.

1) There is a connector that extends from the appliance to the flue liner.
2) The cross-sectional area of the flue is no more than three times the cross-sectional area of the flue collar of the appli-

ance.

3) If the appliance vents directly through the chimney wall above the smoke chamber, there shall be a noncombustible

seal below the entry point of the connector.

4) The installation shall be such that the chimney system can be inspected and cleaned.
5) Means shall be provided to prevent dilution of combustible products in the chimney flue with air from the habitable

space.

C

.

It may be necessary to positive connect this unit to enhance the performance, if any of the following conditions ex-

ists:
1) Poor Drawing Flue 3) Double Flues 5) Stone Front Fireplace/ or damaged flue liner
2) Oversized Flue (17” x 7) 4) Ash Dump 6) Chimney that does not exceed 12’
Check with your dealer if any of the above conditions exist, before installing your stove. Proper installation is critical to
the performance of the Model 91.

Use Fireplace Kit PA FP91 for installation. An optional oversized fireplace kit is available for larger fireplaces. Check
with dealer.

SAFETY NOTICE
If this appliance is not properly installed, a house fire may result. For your safety, follow the installation directions.
Contact local building or fire officials about restrictions and installation inspection requirements in your area.

STARTER PIPE

SEAL TRIM PANELS WITH INSULA-
TION / AND OR HIGH TEMPERATURE
CAULK

OPTION (A)

REMOVE
DAMPER
OR WIRE
IT OPEN

AIRTIGHT INSU-
LATED CLEAN-
OUT

NOTE: New Buck Corporation grants no
warranty, implied or stated, for the installation
or maintenance of your appliance, and assumes
no responsibility of any consequential damage

Advertising