Alternatives for wall protection, Ceiling exit - close clearance – New Buck Corporation 91 User Manual

Page 18

Advertising
background image

Example: The rear clearance for the Model 91 from page 12 is 18". (See Figure 1.) This clearance may be reduced
by 50% to 9" by using either of the wall protection devices mentioned below.

ALTERNATIVES FOR WALL PROTECTION

Ceiling Exit - Close Clearance

1. Suspend a plumb bob from the ceiling above the

unit so that the weight is hanging in the center of
the flue exit. (A small weight on a string will
serve as a plumb bob.) Mark the ceiling where
the string is suspended to locate the center of the
chimney hole.

2. After locating the center of the hole, install the

ceiling support box, chimney, flashing, and rain.

3. Install Double Wall Connector and chimney

system per manufacturer’s written operating
instructions. See manufacturer’s list of tested
pipes.

CAUTION: Because of the high efficiency and

low flue gas temperature, freestanding catalytic
heaters connected to masonry chimneys with
oversized flue liners may encounter drafting problems
A positive flue liner (optional) may be necessary to
help draft. A poor drafting chimney may result in poor
performance from the Model 91. This is not a defect
of the Model 91 but a defect in the chimney. This is
not a warranty problem with the Model 91. Contact
dealer for possible solutions for chimney.

FIGURE 8

CEILING
SUPPORT BOX

SINGLE WALL
PIPE

BRICK CLEAR-
ANCE REDUC-
TION SYSTEM

BRICK WALL
SPACED OUT I
INCH FROM
PROTECTED
SURFACE

LEAVE I INCH
CLEARANCE FOR
AIR CIRCULATION

AIR CIRCULATION

FLOOR

BRICK WALLS MAY BE ATTACHED TO COMBUSTIBLE WALLS USING WALL TIES
IF BRICK IS USED. BE SURE FLOOR CAN WITHSTAND WEIGHT OF BRICK.

COMBUSTIBLE WALL

WOOD STOVE

CLEARANCE REDUC-
TION STEM SPACED
OUT 1 INCH

COMBUSTIBLE WALL

AIR SPACE

1"

NAIL OR
SCREW
ANCHOR

MINIMUM
24 GAUGE
SHEET
METAL

1 INCH NON-COMBUSTIBLE SPACER SUCH AS
STACKED WASHERS, SMALL DIAMETER PIPE, TUBING
OR ELECTRICAL CONDUIT.

DO NOT USE FASTENERS DIRECTLY BEHIND CHIMNEY
CONNECTOR OR STOVE.

TOP VIEW

COMBUSTIBLE WALL

MINIMUM 24 GAUGE
SHEET METAL

NON-COMBUSTIBLE
SPACERS

FLOOR PROTECTOR

FIGURE 9

OPTIONAL NBC
CAST CHIMNEY
CONNECTOR
(COLLAR)