Ay-xpc9/12phr, R410a, Seer a++ scop a – Sharp AY-XP9RMR-AE-X9RMR User Manual

Page 9: Super deluxe new, Specifi cation, Heating cooling

Advertising
background image

8

SEER A++
SCOP A+

Super Deluxe

NEW

AY-XPC9/12PHR

Multi Space function controls the airfl ow for quick,
constant conditioning

Only 21 dB

Pressing Multi Space button will keep several rooms comfortable. By placing
an indoor unit in the living room, stairwell, or wherever you wish, this function
will quickly heat or cool a number of rooms to the set temperature. Then, the
fan speed and the louver
angle are automatically
controlled to circulate
warm or cool air gently
and uniformly to every
corner.

Pressing the Silent button switches to an extra low
fan speed with 21-dB silence. This combines with
high-density Plasmacluster ions to provide good,
sound sleep.

Specifi cation

HEATING COOLING

Q u i e t

21

dB

Features

Cool/Dry/Heat

Outdoor unit

AE-X9PHR AE-X12PHR

R410A

• Plasmacluster ion device
• Coanda Airfl ow System
• Can be used singly or in

a multi split system
(except for the AY- XPM7PHR)

Model

AY-XPC9PHR

AY-XPC12PHR

3.20 (0.90 – 4.70) 4.0

Heating operation

Capacity (kW)

(Min. – Max.)

SCOP

4.00 (0.90 – 5.00) 4.0

+A
+A

2.50 (0.90 – 3.00) 6.3

Cooling operation

Capacity (kW)

(Min. – Max.)

SEER

3.50 (0.90 – 3.80) 6.3

++A

++A

Model

Indoor

AY-XPC9PHR

AY-XPC12PHR

Outdoor

AE-X9PHR

AE-X12PHR

Preformance*1

Cooling

Energy Effi ciency Class

A++

A++

SEER

6.3

6.3

Pdesign

kW

2.5

3.5

Capacity (Min. – Max.)

kW

2.50 (0.90 – 3.00)

3.50 (0.90 – 3.80)

Input (Min. – Max.)

W

580 (200 – 800)

1,000 (200 – 1,250)

Annual electricity consumption*2

kWh/a

138

193

Heating
(Average
Climate)

Energy Effi ciency Class

A+

A+

SCOP

4.0

4.0

Pdesign

kW

3.2

3.4

Capacity (Min. – Max.)

kW

3.20 (0.90 – 4.70)

4.00 (0.90 – 5.00)

Input (Min. – Max.)

W

800 (170 – 1,380)

1,080 (170 – 1,420)

Annual electricity consumption*2

kWh/a

1,100

1,180

Nominal Effi ciency*3

EER

4.31

3.50

COP

4.00

3.70

Nominal Current*3

Cooling

A

3.2

4.6

Heating

A

3.8

5.0

Sound Pressure Level*4 (Cool)

Indoor (Hi/Lo)

dB(A)

39/26

42/27

Outdoor

db(A)

48

49

Sound Power Level (Cool)

Indoor (Hi)

54

56

Outdoor

62

64

Airfl ow Volume (Hi, Cool)

m3/min

9.7

10.8

Operation Range (Outdooor)

Coolong

°C

-10 – 46

-10 – 46

Heating

°C

-15 – 24

-15 – 24

Model

Indoor

AY-XPC9PHR

AY-XPC12PHR

Outdoor

AE-X9PHR

AE-X12PHR

Power Supply

Outdoor

V/Phase/Hz 220 – 240/single/50 220 – 240/single/50

Dimensions

Indoor (WxHxD)

mm

920x290x240

920x290x240

Outdoor (WxHxD)

mm

780x540x269

780x540x269

Weight

Indoor

kg

10

10

Outdoor

kg

36

38

Min. – Max. Pipe Lenght

m

3 – 20

3 – 20

Max. Height Difference

m

10

10

Max. Chargless Lenght

m

10

10

Pipe Diameter

Liquid Side

inch

1/4

1/4

Gas Side

inch

3/8

3/8

Refrigerant (GWP*5)

kgCO

2

eq.

R410A (1975)

R410A (1975)

*1 According to EN14825
*2 Energy consumption “XYZ” kWh per year, based on standard test results. Actual energy

consumption will depend on how the appliance is used and where it is located.

*3 According to EN14511
*4 Sound pressure level is measured according to JIS C 9612.
*5 Refrigerant leakage contributes to climate change. Refrigerant with lower global
warming potential (GWP) would contribute less to global warming than a refrigerant

with higher GWP, if leaked to the atmosphere. This appliance contains a refrigerant fl uid

with a GWP equal to 1975. This means that if 1 kg of this refrigerant fl uid would be leaked

to the atmosphere, the impact on global warming would be 1975 times higher than 1 kg

of CO

2

, over a period of 100 years. Never try to interfere with the refrigerant circuit

yourself or disassemble the product yourself and always ask a professional.

Advertising