Whirlpool UXT4230ADS User Manual

Whirlpool Kitchen

Advertising
background image

A. 18" (45.7 cm) minimum distance from electric cooking surface.

24" (61.0 cm) minimum distance from gas cooking surface.
30" (76.2 cm) suggested maximum above the cooking surface.

B. 18" (45.7 cm) minimum clearance - upper cabinet to countertop.

C. 30" (76.2 cm) minimum cabinet opening width for 30" (76.2 cm)

models and 36" (91.4 cm) minimum cabinet width for 36"
(91.4 cm) models.

D. 12" (30.5 cm) cabinet depth.

E. 36" (91.4 cm) base cabinet height.

B

A

C

D

E

Range Hood - 30" (76.2 cm) and 36" (91.4 cm)

PRODUCT MODEL NUMBERS

OVERALL DIMENSIONS

UXT4230AD

UXT4236AD

Electrical:

A 120 volt, 60 Hz., AC only, 15-amp, fused electrical

circuit is required.

Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.

Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.

Ref. W10646404A

3/14

CABINET OPENING DIMENSIONS

1"

(2.5 cm)

4

¹⁵⁄₁₆

"

(12.5 cm)

6

⁹⁄₁₆

" (16.7 cm) or

9

⁹⁄₁₆

" (24.4 cm)

29

¹⁵⁄₁₆

" (76.0 cm) or

35

¹⁵⁄₁₆

" (91.0 cm)

18

⁵⁄₈

"

(47.3 cm)

1¹⁄₂

"

(3.8 cm)

9"

(22.9 cm)

2"

(5.1 cm)

⁷⁄₈

"

(2.2 cm)

VENTING REQUIREMENTS

Top Venting

Wall Venting

A. 7" (17.8 cm) round vent

through roof
(purchased separately).
3

¹⁄₄" x 10" (8.3 x 25.4 cm)

rectangular vent through the
roof (purchased separately).

B. Roof cap with damper

(purchased separately)

A. 7" (17.8 cm) round vent out

the top and through the wall
(purchased separately).
3

¹⁄₄" x 10" (8.3 x 25.4 cm)

rectangular vent through the
wall or out the top (purchased
separately).

B. Wall cap with damper

(purchased separately)

A

B

A

B

Example vent system

Wall cap

90˚ elbow

2 ft (0.6 m)

6 ft (1.8 m)

1 - 90° elbow

= 5.0 ft (1.5 m)

1 - wall cap

= 0.0 ft (0.0 m)

8 ft (2.4 m) straight

= 8.0 ft (2.4 m)

System length

= 13.0 ft (3.9 m)

Maximum Recommended Length

7" (17.8 cm) Round Vent

= 50 ft (15.2 m)

3

¹⁄₄" x 10" (8.3 x 25.4 cm)

= 35 ft (10.7 m)

Rectangular Vent

Calculating Vent System Length
To calculate the length of the system you need, add the equivalent feet (meters) for
each vent piece used in the system.

Vent System

Vent Piece
90° elbow

5.0 ft
(1.5 m)

3

¹⁄₄" x 10" (8.3 cm x

12.0 ft

25.4 cm) flat elbow

(3.7 m)

7" (17.8 cm) wall cap

0.0 ft
(0.0 m)

3

¹⁄₄" x 10" (8.3 cm x

4.5 ft

25.4 cm) to 7" (17.8 cm)

(1.4 m)

3

¹⁄₄" x 10" (8.3 cm x

5.0 ft

25.4 cm) to 7" (17.8 cm)

(1.5 m)

90° elbow