PRODUCT MODEL NUMBERS

GXW7230DA

ELECTRICAL REQUIREMENTS

• A 120 volt, 60 Hz, AC only, 15- or 20-amp, fused electrical circuit is required.

VENTING REQUIREMENTS

For Non-Vented (recirculating) Installations
If it is not possible to vent cooking fumes and vapors to the outside, the hood
can be used in the non-vented (recirculating) version, by fitting a charcoal filter
and the deflector. Fumes and vapors are recycled through the top grille. See the
“Assistance or Service” section for information on ordering.

Calculating Vent System Length

To calculate the length of the system you need, add the equivalent feet (meters)
for each vent piece used in the system.

30" (76.2 CM) Wall-Mount Canopy Range Hood

Because Whirlpool Corporation policy includes a continuous commitment to improve our
products, we reserve the right to change materials and specifications without notice.

Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.

Ref. W10458667A

9/13/12

Roof Venting

Wall Venting

Non-vented

(recirculating)

A. Roof cap
B. 6" (15.2 cm)

round vent

A. Wall cap
B. 6" (15.2 cm)

round vent

A. Deflector
B. 6" (15.2 cm)

round vent

A

A

B

B

B

A

Example vent system

The following example falls within the maximum recommended vent
length of 35 ft (10.7 m).

LOCATION REQUIREMENTS

Have a qualified technician install the range hood. It is the installer's
responsibility to comply with installation clearances specified on the
model/serial rating plate. The model/serial rating plate is located behind
the left filter on the rear wall of the vent hood.
Canopy hood location should be away from strong draft areas, such as
windows, doors and strong heating vents.

For Mobile Home Installations
The installation of this range hood must conform to the Manufactured
Home Construction Safety Standards, Title 24 CFR, Part 328 (formerly
the Federal Standard for Mobile Home Construction and Safety, Title 24,
HUD, Part 280) or when such standard is not applicable, the standard
for Manufactured Home Installation 1982 (Manufactured Home Sites,
Communities and Setups) ANSI A225.1/NFPA 501A, or latest edition, or
with local codes.

PRODUCT DIMENSIONS

Vent Piece

6" (15.2 cm) Round

45° elbow

2.5 ft (0.8 m)

90° elbow

5.0 ft (1.5 m)

Maximum equivalent vent length is 35 ft (10.7 m).

1 - 90° elbow
1 - wall cap
8 ft (2.4 m) straight

= 5.0 ft (1.5 m)
= 0.0 ft (0.0 m)
= 8.0 ft (2.4 m)

Length of system

= 13.0 ft (3.9 m)

90 elbow

6 ft (1.8 m)

2 ft

(0.6 m)

Wall cap

*For non-vented (recirculating) installations

**For vented installations

30" (76.2 cm)

10"

(25.4 cm)

20" (50.8 cm)

14

¹⁄₈"

(35.9 cm)

7

¹⁄₄"

(18.4 cm)

8

¹⁄₈"

(20.7 cm)

*28

⁷⁄₈" (73.3 cm) min.

42

¹⁄₁₆" (106.9 cm) max.

**28

³⁄₈" (72.0 cm) min.

38" (96.6 cm) max.

1 " (4.0 cm)

Page 1 of 2