Whirlpool UXL5430BSS User Manual

30" hood liner

Advertising
background image

Venting Methods

This range hood is factory set for venting through the roof or through

the wall.
The vent system needed for installation is not included. A 6"

(15.2 cm) round vent system is recommended.

Calculate Vent System Length

The recommended vent system is 6" (15.2 cm) round vent with a

maximum length of 35 ft (10.7 m). For the best performance, use no

more than three 90° elbows.
To calculate the length of the system, add the equivalent feet (meters)

for each of the vent pieces used in the system.

Vent Piece

6" (15.2 cm)

45° elbow

2.5 ft
(0.8 m)

90° elbow

5.0 ft
(1.5 m)

PRODUCT MODEL NUMBERS

CABINET DIMENSIONS

UXL5430B

Electrical Requirements:

A 120 volt, 60 Hz, AC only, 15- or 20-amp, fused electrical

circuit is required. A time-delay fuse or circuit breaker is also

recommended. It is recommended that a separate circuit

serving only this range hood be provided.

This range hood is equipped with a power supply cord having

a 3 prong grounding plug.

30" Hood Liner

Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.

Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.

Ref. W10487239D

3/12/14

A. 12" (30.5 cm) min. upper

cabinet height

B. 30" (76.2 cm) or 36" (91.4 cm)

cabinet opening width*

C. 24" (61 cm) min. 36" (91.4 cm)

suggested max. bottom of
cabinet to cooking surface

D. 12" (30.5 cm) cabinet depth*

E. 15" (38.1 cm) min. clearance

upper cabinet to countertop

F. 36" (91.4 cm) base cabinet

height

F

A

B

C

D

E

VENTING REQUIREMENTS

Vent system must terminate to the outside, except for nonvented

(recirculating) installations.

Do not terminate the vent system in an attic or other enclosed area.

Do not use a 4" (10.2 cm) laundry-type wall cap.

Use metal vent only. A rigid metal vent is recommended. Plastic or

metal foil vent is not recommended.

The length of the vent system and number of elbows should be

kept to a minimum to provide efficient performance.

For the most efficient and quiet operation:

Use no more than three 90° elbows.

Make sure there is a minimum of 24" (61.0 cm) of straight vent

between the elbows if more than 1 elbow is used.

Do not install 2 elbows together.

The vent system must have a damper.

Use clamps to seal all joints in the vent system.

Use caulking to seal exterior wall or roof opening around the cap.

The size of the vent should be uniform.

Roof Venting

Wall Venting

A. 6" (15.2 cm) vent through

the roof

B. Roof cap

A. 6" (15.2 cm) vent through

the wall

B. Wall cap

A

B

A

B

Page 1 of 2

*

NOTE:

30" (76.2 cm) cabinet width can be 12" (30.5 cm)

deep or 18" (45.7 cm) deep cabinets.
36" (91.4 cm) cabinet width requires 18" (45.7 cm) deep
cabinets.
For 18" (45.7 cm) deep cabinets, an optional “Face Panel
Rear Extension” (30" [76.2 cm]) or “Face Panel” (36"
[91.4 cm]) must be purchased separately. See “Assistance
and Service” section to order.