Bradley Smoker AERADA 1000 Series S53-327 DC User Manual

Page 7

Advertising
background image

Installation

Aerada 1000/1100 Series

Bradley Corporation • 215-1628 Rev. A; EN 08-201

5/21/08

7

9 Mount mixer handle (only for faucets with external mixer)

Result: The faucet is now mounted.

A - Setting Cleaning Mode

Setting the cleaning mode will make the faucet inactive for 90 seconds.

1 Enable

“Manual

Setting”

Mode

> See “Enabling Manual Setting Mode” section

2 Fully cover sensor with hand, until water fl ow stops. (This takes 5 seconds.)

3 Remove hand.

Result: The Cleaning Mode is now active. For the next 90 seconds, the faucet

will be inactive.

B - Setting Normal Mode

Setting the normal mode will allow the faucet to activate only when it senses a
hand presence.

1 Enable

“Manual

Setting”

Mode

> See “Enabling Manual Setting Mode” section

2 Fully cover sensor with hand. Water fl ow stops after 5 seconds - Continue to

hold on for one (1) additional water pulse.

3 Remove hand.

Result: Normal Mode is now activated.

C - Setting Metering Mode (10 seconds)

Setting the metering mode will allow the faucet to activate for a full 10 seconds
after if senses a hand presence.

1 Enable

“Manual

Setting”

Mode

> See “Enabling Manual Setting Mode” section

2 Fully cover sensor with hand. Water fl ow stops after 5 seconds - Continue to

hold on for another two (2) additional water pulses.

3 Remove hand.

Result: Metering Mode is now activated for 10 seconds.

Advertising
This manual is related to the following products: