Fig. 13 Maximum vent and combustion air lengths

Vent material

The GWH-345/450-ESR requires 3 inch sealed single
wall stainless steel vent pipe (AL29-4C). Use of any
other vent material will void the manufactures warranty
and may result in a hazardous condition. For specific
questions concerning vent material, specifications,
usage or installation, contact the vent manufacturer
directly.

Contact your Bosch supplier for stocked vent material.

Vent Safety System

The GWH-345/450-ESR will shut down if inadequate
exhaust venting is detected or a lack of combustion air
is provided to the unit; see troubleshooting section on
page 32. Correct the problem and then reset the heater
before operating.

3.6.2

Vent connections and air inlet restrictors

Exhaust vent connection

B Attach the flue gas exhaust accessory (8 705 504

142) to the top of the unit (position 1) using the 4
screws and gasket provided

B Insert 3" single wall stainless steel vent pipe into

exhaust vent adapter 1.5" and tighten the clamp
(position 2).

Note: Failure to fully insert and tighten vent pipe may
cause flue gas leakage or condensate damage that is
not covered under the manufacturer's warranty.

Company

Contact information

Z-flex

www.z-flex.com
800-654-5600

ProTech
Industries

www.protechinfo.com
800-766-3473

Heat-Fab

www.heatfab.com
800-772-0739

Table 4 Vent manufacturer contact information

Reduce maximum
length 6 ft for each
90 elbow after the
first one and 3 ft for
each 45 elbow.

Vent pipe

Combustion
air intake

Z flex

Protech

Heat Fab

3” Horizontal
terminator

TEE only

TEE only

9390 TEE

3” Vertical
terminator

2SVSRCF03

FSRC3

5300CI

90°
Condensate
drain Tee

2SVEVWCF03

FST3 &

FSDF3

93PLSTEE

Horizontal
Condensate
drain

2SVEDWCF03

FSHD03

9321

Vertical
Condensate
drain

2SVSEVDP03

N/A

N/A

Condensate
Drain Tube

2SVEDTK

N/A

7000TUBE

Table 5 Approved vent termination and condensate

drain part numbers (subject to change)

Advertising