4 power, 5 recirculating water temperature, 6 temperature and hot water flow – Bosch PROTANKLESS GWH 345/450 ESR User Manual

Page 28: 7 freeze protection

Advertising
background image

6 720 607 909

28

Operating instructions

4.4

Power

On

To start the appliance:

B press the ON/OFF

button.

LED (fig. 31) goes orange.
When the burner is working, the LCD display shows
the symbol

.

Fig. 32

Off

To shut down the appliance:

B press the ON/OFF

switch to OFF position.

4.5

Recirculating water temperature

Water temperature can be regulated in a range of
113°F to 190°F. The heater modulates the burner flame
according to current demand selected on left knob.
To select water temperature:

B Rotate recirculating water temperature selector

in order to change heating recirculating temperature
(ranging from 113°F to 190°F).
The display will show this symbol

and blink the

selected temperature.
If the burner is on, symbol

goes ON.

Fig. 33 Recirculating water temperature adjustment

4.6

Temperature and hot water flow

Choose one the following:

• If using a tank mounted Aquastat, set temperature on

Aquastat control (left knob should be in maximum
position).

• To activate and use the appliance domestic

temperature dial, a 12 kOhm thermistor is required
(part number 8 714 500 034) (See 2.6, Page 8 for
wiring diagram).

B Connect the 12kOhm thermistor blue wire to the

DHW NTC terminal block.
Install the sensor in the tank well.

Hot water temperature can be set from 50°F to 158°F
using hot water temperature selector

(Fig. 34).

Fig. 34 Hot water temperature adjustment

4.7

Freeze protection

B Do not disconnect the electric supply from heater.

B Do not install in unheated areas which can

experience freezing temperatures.

B Do not use non-potable additives like glycol.

Freeze protection

Freeze protection is always assured by the operation of
the appliance.
If the primary NTC (temperature) sensor detects
temperatures 9°F below the selected temperature, the
appliance starts on minimum power until the sensor
reads selected temperature.
In case of minimum setpoint it will start at 41°F.

Thermostat

knob position

DHW

temp.

Min.

approx. 50°F (10°C)

Max.

approx. 158°F (70°C)

Table 14

Domestic hot water temperature
adjustment

Advertising