SERVICING INSTRUCTIONS

ACCESS PANELS

Each warmer plate has a center stud which screws into a
bracket. Warmer plates on Canadian brewers are secured with
a nut. Remove button plug on bottom of brewer to access nut
on warmer plate. Remove warmer plates by turning counter-
clockwise.

Solenoid door is held by two screws and a retaining lip.

Front Panel (In-Line Models) and Top / Rear Panel (3-Station
Models):

a. Remove warmer plate by turning counter-clockwise

until it unscrews.

b. Remove screws from two retaining clips under

warmer plate.

c. Lift off panel.


Front Panel (3-Station Models):

a. Remove warmer plates by turning counter-clockwise

until they unscrew.

b. Remove screws from two retaining clips under each

warmer plate.

c. Remove three screws from bottom-side of front lip.

d. Pull bottom of panel forward until it clears.


Top Panel (All Models):

a. Remove two screws from rear of top panel.

b. Lift rear of panel, remove to rear.

CAUTION:

SHOCK HAZARD

Opening access panels or
removing warmer plates on this
brew may expose uninsulated
electrical components.
Disconnect brewer from
electrical power before
removing any panel or warmer
plate.

Fig. 9 Access Panels

11