OPERATION

Fig. 4 Brewer Operation Diagram

A. START-UP

For initial start-up, or if the brewer has not been used for an

extended period of time:

♦ Be sure spray disk and brew gasket are properly installed in the

brew head.

♦ Be sure the water supply is properly connected and the water

supply valve is turned ON.


♦ Be sure the WATER TANK IS FILLED

BEFORE

plugging the brewer into a receptacle, or otherwise

connecting brewer to electrical power THE WATER TANK MUST

BE

FILLED

. Place an empty decanter under the brew head. Lift

the pour-over cover then pour warm tap water into the pour-over

opening until water flows from the brew head. When water stops

dripping from the brew head, empty the container.

Once the tank is full of water, connect the brewer to electrical

power. The heating elements will begin heating the water in the

tank. When the water has reached the proper temperature, the

“READY To BREW” light will glow.

IMPORTANT:
Tank must be full of water
before connecting brewer
to electrical power.
Heating elements will be
damaged if allowed to
operate without being fully
submerged in water.
Damage caused by
operating the brewer
without water in the tank
is NOT COVERED BY
WARRANTY

.

6