Bosch BOSCH Dryer User Manual

Page 10

Advertising
background image

10

1

3

2

1 ć Exhaust air outlet on the rear of the

appliance (standard)

2 ć Exhaust air outlet on the side (optional)
3 ć Exhaust air outlet on the underside of the

appliance (optional)

Special exhaust air connections

must be obtained from your dealer

or part supplier for either

connection type (see page 11).
- Side exhaust kit
- Bottom exhaust kit
A qualified technician should

change the exhaust air outlet to the

optional connection location.
Ductwork

To ensure optimum performance,

the ducting system of the dryer

should be as short as possible with

a minimum number of elbows. Your

dryer will work best when the

venting system has as few air flow

restrictions as possible. Exhaust

ducting which is longer than

recommended may extend drying

time, cause lint to accumulate and

affect dryer performance and dryer

lifeĆtime.
FourĆinch (approx. 100 mm)

diameter ducting should be used.

Use either rigid metal or flexible

metal ducting material.

DO NOT use plastic or nonĆmetal

duct with this dryer.

DO NOT assemble the ductwork

with screws or fasteners that

extend into the duct. They will serve

as an accumulation point for lint.

Joints should be secured with duct

tape.

All joints should be tight to avoid

leaks. The male end of each duct

section must point away from the

dryer.
Whether connecting to an existing

venting system or a new venting

system, make sure that all ducting

is clean and free of lint.
The maximum permitted length for

both rigid and flexible metal duct is

shown in the table below.

Number of

90° Turns

or Elbows

Rigid Duct

Flexible Duct

0

66 ft.

(2011 cm)

45 ft.

(1372 cm)

1

56 ft.

(1707 cm)

36 ft.

(1097 cm)

2

48 ft.

(1463 cm)

29 ft.

(884 cm)

3

39 ft.

(1189 cm)

22 ft.

(671 cm)

4

30 ft.

(914 cm)

16 ft.

(488 cm)

Note:

Side and bottom exhaust

installations have a 90° turn inside

the dryer. To determine maximum

exhaust length, add one 90° turn to

the chart.

More than two 90

°

turns are not

recommended. For best

performance, separate all turns by

at least 4 ft. of straight duct,

including distance between last turn

and exhaust hood.

Exhaust vent hood
The exhaust duct must end with an

approved exhaust vent hood with

swing out damper(s). DO NOT use

an exhaust vent hood with

magnetic latches.
To avoid exhaust restriction, the

outlet must be a minimum of

12 inches (30 cm) above ground

level or any other obstructing

surface.

Required parts
The parts required for the exhaust

air system (elbows, lines, exhaust

air outlets) are not included in

standard delivery of the dryer.

Advertising