10. Check the U.L. strain relief

clamp to make sure that it is

tight and cannot be turned.

11. Replace the cover on the

terminal block and fasten in

place.

i

Make sure that the U.L. strain

relief clamp is outside the

cover!

The appliance is now ready to be

plugged into the 4Ćwire receptacle

of the power rating.
Connecting 3Ćwire power supply

cord

1. Remove the screws from the

cover of the terminal block

located at the top rear of the

appliance.

2. Make sure that there is

a grounding strap.

3. Fix the strain relief clamp to the

angle bracket. Tighten the nut.

4. Loosen the 2 screws labeled L

and the screw labeled N in the

terminal block.

5. Thread the 3Ćwire cable

through the U.L. strain relief

clamp.

6. Tighten the screws (2.5 Nm) on

the U.L. strain relief clamp so

that the power cord cannot be

moved.

7. Attach the 2 power cord outer

conductors (red and black) to

the 2 terminals labeled L and

the remaining power cord

conductor (white) to the

terminal labeled N.

8. Tighten all 3 screws (3 Nm) so

that the power conductors are

held in place securely.

9. Check the U.L. strain relief

clamp to make sure that it is

tight and cannot be turned.

10. Replace the cover on the

terminal block and fasten in

place.

i

Make sure that the U.L. strain

relief clamp is outside the

cover!

Additional grounding procedure

- Some local regulations may

require a separate ground.

In such cases, the required

accessory ground wire, clamp

and screw must be purchased

separately.

- Never ground the dryer to

plastic plumbing lines, gas lines

or water pipes.

Grounding instruction
This appliance must be grounded.

In the event of a malfunction or

breakdown, grounding will reduce

the risk of electric shock by

providing a path of least resistance

for the electric current.

For Canada the dryer comes with a

cord which has an equipment

grounding conductor and a

grounding plug. The plug must be

plugged into an appropriate outlet

which has been properly installed

and grounded in accordance with

all local regulations and ordinances.

d

WARNING

d

Improper connection of the

equipment grounding conductor

may result in electric shock.

Have the appliance checked by

a qualified electrician or service

technician if you are in doubt as

to whether the dryer has been

properly grounded.

Exhaust air connection

d

WARNING

d

1. To reduce the risk of fire, this

dryer MUST BE EXHAUSTED

OUTDOORS.

2. To reduce the risk of fire, do

not use the ductwork longer

than recommended.

3. DO NOT use a plastic or

nonĆmetal duct with this dryer.

4. DO NOT use a duct smaller

than 4 inches in diameter.

5. DO NOT use exhaust hoods

with magnetic latches.

6. DO NOT exhaust the dryer into

a chimney, furnace cold air

duct, attic, crawl space, or any

other ductwork used for

venting.

7. DO NOT install a flexible duct

in an enclosed wall, ceiling or

floor.

8. DO NOT crush or kink the

duct.

9. Do clean and inspect the

exhaust system on a regular

basis; at least once a year.

10. The exhaust duct must

terminate in a manner to

prevent back drafts or entry of

birds or other wildlife.

The Bosch dryers are intended to

be vented outdoors. To prevent

buildĆup of moisture and

accumulation of lint indoors, as well

as to maintain maximum drying

efficiency, it is recommended that

the dryer is vented outdoors.
Exhaust air outlet on the dryer

The dryer is delivered with an

exhaust air outlet on the rear of the

appliance.
To take account of the spatial

requirements and an existing

exhaust air system, the following

connection options are possible for

the exhaust air outlet:
- on right side of the appliance,

- on the underside of the

appliance.

Advertising