Electrical connection

d

WARNING

d

Power cord must be connected

by a qualified person only.
Connect to individual Brunch

Circuit.
Do not use an adapter.

Do not use an extension cord.
Do not remove ground prong.

For CANADA

Your dryer comes with a power

supply cord, CSA listed in Canada.
The Bosch dryer requires a 4Ćwire

receptacle.

When installing the receptacle for

the dryer cord, ensure that the

power supply cord is accessible

when the dryer is in the installed

position.
The power cord should only be

replaced by a qualified person.

Use a 4Ćwire power supply cord

(see electrical connection U.S.A.

below).
For U.S.A.

Your dryer comes without a power

supply cord.

The power cord must

meet the following requirements:
- UL listed in the USA
- 208 ć 240 volt rated (minimum)
- 30 amps
- Type SRDT or DRT (UL 2158)
- Five feet long (minimum)

d

WARNING

d

Power cord must be connected

by a licensed electrician only.
Use only a U.L. approved

30 amp power cord with strain

relief clamp -

note manufacturer's instructions.
Do not plug end of power cord

into a live receptacle before conĆ

necting power cord to appliance

terminals and closing junction/

splitter box as described below.
Do not reuse old power cord.

Cord must have closed loop or

upturned end wire terminating

connectors.
Do not make a sharp bend or

crimp wiring/conductor at conĆ

nections.
Only a 4Ćconductor cord shall

be used when the appliance is

installed in a mobile home or an

area where the local codes do

not permit grounding through

the neutral.

Connecting 4Ćwire power supply

cord

1. Remove the screws from the

cover of the terminal block

located at the top rear of the

appliance.

1

2

3

1 - terminal block
2 - grounding strap
3 - Angle bracket for strain relief clamp

2. Loosen the bottom screw of

the grounding strap. Place the

screw to the GROUND

location. Planish the grounding

strap and hang loosely.

3. Fix the strain relief clamp to the

angle bracket. Tighten the nut.

4. Loosen the 2 screws labeled L

and the screw labeled N in the

terminal block. and the screw

of the GROUND terminal.

5. Thread the 4 wire cable through

the U.L. strain relief clamp.

6. Tighten the screws (2.5 Nm) of

the U.L. strain relief clamp so

that the power cord cannot be

moved.

7. Attach the power cord ground

conductor (green) to the

GROUND terminal. Tighten the

screw (2.5 Nm) so that the

ground conductor is held

securely in place.

8. Attach the 2 power cord outer

conductors (red and black) to

the 2 terminals labeled L and

the remaining power cord

conductor (white) to the

terminal labeled N.

9. Tighten all 3 screws (3 Nm) so

that the power conductors are

held securely in place .