Service Mode

7-9

5975039 BARCOVISION 508 120198

the CRT run in cycle will start when pressing ENTER. If no such a

block is available, the projector cannot run the CRT run in option and

leaves the adjustment mode.

If you still want to run CRT run in cycle, create first a memory block

on an internal # pattern and restart the CRT run in option.

ENTER starts the 'CRT run in' when an internal generated # pattern

is available.

EXIT returns to the Path Selection main menu.

CRT RUN IN CYCLE

All flashing white pattern

will be generated until

<EXIT> is pressed.

The projector only uses

memory blocks adjusted

on an internal # pattern;

if no such block is

available, the projector

can't run the procedure

and leaves the adjustment

mode

<ENTER> to continue

<EXIT> to cancel

I2C Diagnostics

Highlights 'I2C Diagnostics' by pushing the control disc up or down

and press ENTER.

The I2C diagnostics menu gives an overview of the I2C failures inside

the projector.

To scroll through the failure list, push the control disc up or down.

The I2C address, IC number and module name will be given in I2C

diagnostic menu.

When no errors are detected, the following message will appear on

the screen :

"No errors on i2c-bus detected".

Select with or

then <ENTER>

<EXIT> to return.

SERVICE MODE

PROJECTOR SET-UP

MEMORY MANAGEMENT

COMMON SETTINGS

I2C DIAGNOSTICS

Scroll with or

then <ENTER>

<EXIT> to return.

I2C DIAGNOSTICS

Failures :

addr

IC number

mod.name

48H

IC200

DECODER