About advanced features and operation – Bryant PROGRAMMABLE DIGITAL TERMOSTAT OM 17-101 User Manual

Page 5

Advertising
background image

Page 5

Advanced Setup Table

• CLOCK BACKUP — In the event of a power loss, the

thermostat internal clock will continue to keep proper
time for a minimum of 48 hours without external power
or batteries.

• TWO-STAGE OPERATION — The Second Stage of

heat (Heat pump models only) is turned on when (

1

)

the first Stage has been on for a minimum of two min-
utes,

and

(

2

) the temperature spread from the set

point is equal to or greater than:

the set point plus the

deadband, plus 2 degrees.

• MINIMUM HEAT/COOL SET POINT DIFFERENCE —

The Heat and Cool set points will not be allowed to
come any closer to each other than the value set in
Advanced Setup

Step 5, on page 4

. This minimum

difference is enforced during Auto changeover and
Program On operation.

• ENERGY SAVING SMART FAN — If Fan On is

selected, the fan will run continuously at all times,
except in Off,

and

will only run if there is a heating or

cooling demand in Unoccupied periods.

• OVERRIDE — As explained on

page 3

, pressing the

Override button during a programmed, Unoccupied
period will force the thermostat into Occupied 1, tem-
porarily, up to 4 hours. If the Override button is
pressed during an Occupied period, the thermostat
will be forced into Unoccupied and the occupied num-
ber

(1,2 or 3)

, it was forced out of will be turned off,

only for that day.
During Override periods the set points may be
adjusted, but they will not be remembered after Over-
ride ends.

• HEAT — First Stage = Heat Pump. Second Stage =

Heat Pump and Electric Heat.

• FAN PURGE TIMER — When this feature is activated,

the fan will turn on during Unoccupied at a preset
amount of time prior to Occupied 1. This preoccu-
pancy fan purge timer may be set as instructed on

page 4, Step 12

, from 0 to 3 hours. 0 = this feature

turned off.

• KEYPAD LOCK — To prevent unauthorized use of the

thermostat, the front panel buttons may be disabled.
To disable, or ‘lock’ the keypad, press and hold in the
Mode button. While holding the Mode button in,

simultaneously press the Up and Down buttons. The

Locked

icon will appear on the display.

To

unlock

the buttons, again press and hold the Mode

button. While holding the Mode button in, simulta-
neously press the Up and Down buttons in together.
The

Locked

icon will disappear from the display.

• DRY CONTACT SWITCH — The terminals are ‘nor-

mally open’. Closing or completing the circuit will
cause the thermostat to enter Occupied 1. This feature
allows an external device such as a Central Time
Clock, Occupancy Sensor, or a Telephone activated
device to force 1 or more thermostats into Occupied 1.
For the Dry Contact to work the thermostat must be in

Program On

.

Set Occupied 1 to Off

for all 7 days,

so

the Contact closure will be in control. When the ther-
mostat is forced into Occupied 1 via the Dry Contact
closure, the icon

Occupied 1

will blink.

• HOLIDAY MODE — This feature forces the thermostat

into Unoccupied for a preset duration, up to 99 days.
The Holiday setup display is entered as follows:

The thermostat will enter the Holiday mode when the
clock crosses midnight.
During Holiday mode Unoccupied set points are
enforced.
The Override button is active during Holiday mode. It
will override to Occupied 1 settings up to 4 hours then
return to Holiday mode. The Dry Contact Switch is
ignored.
The thermostat will exit Holiday mode at midnight of
the final programmed day. To terminate Holiday imme-
diately, enter the Holiday setup screen and select 0.

• SOFT START — This feature is utilized in multiple

thermostat installations controlled by the Dry Contact
terminals. Assigning a unique Soft Start number to
each thermostat will stagger the turn on times, even
though the Dry Contact closes, for all the thermostats
connected, at the same time. Each Soft Start number

STEP NO.

DESCRIPTION

RANGE

FACTORY DEFAULT

1

Time of day clock set

24 hour

12:00 Am

2

Day of the week

Su - Sa

M

3

Heat Pump

Off / On

Off

4

Deadband or Temperature swing

1 - 6 F

2 F

5

Forced minimum difference
heat/cool

0 - 6 F

2 F

6

Cycles per hour

d, d1, 2 - 6

6

7

Security Levels

0 - 3

0

8

Maximum allowable Heat set point

35 - 99 F

80 F

9

Minimum allowable Cool set point

35 - 99 F

65 F

10

Fahrenheit or Celsius

F / C

F

11

Thermoglow™ backlight

Off / On

On

12

Fan Purge timer

0:00 - 3:00

0:00

13

Soft Start

0 - 99

0

About Advanced Features and Operation

Heat

Set Point

Cool

Set Point

1st Stage

turn on

1st Stage

Low

2nd Stage

turn on

2nd Stage

Med

Med

Heating

Cooling

3rd Stage

High

Dead
Band

Dead
Band

2 degrees

2 degrees

2 degrees

2 degrees

High

Low

Fan Speeds

Program On

Pm

W

Locked

unoccupied

ON

:

CK1

GND

1

2

HOLIDAY

Advertising