Page 6

represents a multiple of 30 seconds from the Dry Con-
tact closure.

For example, 1 = turn on 30 seconds after

Dry Contact closure, 2 = turn on 60 seconds after clo-
sure, 3 = turn on 90 seconds after closure, and so on.
See

page 4, Step 13,

to configure the thermostat for

Soft Start.

• DUAL SET POINT BEHAVIOR — The adjustable set

point range is: 35 to 99 degrees in Fahrenheit and 7 to
35 degrees in Celsius. When in the modes Heat or
Cool, this adjustable range is unhampered.
When adjusting any Auto mode, including program-
ming Occupied and Unoccupied periods, the thermo-
stat will not allow the Heat set point to get closer to the
Cool set point than the value programmed as the mini-
mum difference in

Step 5, page 4.

When entering the Auto mode from Cool, the Heat and
Cool set point temperatures will remain spread apart
by the amount that they were adjusted, prior to enter-
ing Auto.
For example: If the Cool set point was set to 80 while
in the Cool mode and the Heat set point was adjusted
to 70 while in the Heat mode, upon entering the Auto
mode the Heat and Cool set points would be 80 and
70.

Both

set points would then move up and down

together, (in this example spread by 10 degrees), by
pressing the up or down buttons.
To move the Heat and Cool set points closer together,
enter the Cool or Heat mode by pressing the Mode
button, then adjust the set point(s) closer together.
Heat is limited to how close it can come to Cool by

Step 5, page 4

.

• REMOTE SENSORS

(Optional Accessory)

— When

connected to terminals RS+5, RS, and GND on the
back of the thermostat, the thermostat will read the
temperature from the Remote Sensor and ignore the

temperature sensor inside the thermostat. The thermo-
stat automatically recognizes when a Remote Sensor
is connected. When reading the temperature from the

remote, the degree icon
above the room tempera-
ture blinks once a second.

The Override button

on

the Remote Sensor works
slightly different than the
Override button on the
front panel. Each press of
the ‘External’ Override
button adds 2 hours to the
override timer. If the timer

was already active,

the first button press will round the

runtime to either

2:00 or 4:00.

Subsequent button presses will not wraparound as the
Override button on the thermostat does, so the second
or greater button press will set the runtime to 4:00. The
Locked feature has no effect on the external Override
button. The

wired

Remote Sensor is connected to the

thermostat with

up to 500 ft of 20 ga. or 300 ft of

18 ga.

thermostat wire

.

See the Remote Sensor

instructions for further details.

• FACTORY DEFAULTS — Before restoring factory

defaults, set thermostat to OFF mode. If, for any rea-
son it is desirable to return all stored settings back to
the factory default settings, press the Mode button.
While holding the Mode button in, press the Fan button
for 5 sec. All icons will appear. Press and hold in the
Fan button until

Fd

appears. This resets all factory set-

tings.

To calibrate room temperature,

press the Up

and Down buttons at the same time twice. At this point
use the Up and Down buttons to calibrate room tem-
perature, if needed. Press the Mode button to return to
normal operation.

Optional

Remote Sensor

Optional Sensor

OVER

RIDE