Ready to brew water temp: 205, Brew lockout? no done yes – Bunn W/SMART FUNNEL S/N SNG0033000 & UP User Manual

Page 13

Advertising
background image

Page 13

MAIN SCREEN

This screen will be shown when the brewer is ready

for use. The screen displays the water temperature

in the tank. When the water in the tank reaches the

correct set temperature, the display will change from

HEATING to READY TO BREW.

PROGRAMMING LOCKOUT SWITCH (mounted on

main control board)

This switch can be set to prevent access to the

programming levels of the brewer. Once all the cor-

rect brew settings are programmed, the operator can

set the switch to the "DISABLE" position to prohibit

anyone from changing the settings.

BREW LOCKOUT

This function allows the operator to prevent or

allow brewing if the water temperature is less than

the set READY temperature.

To access this function screen press and hold the

® symbol. Release the ® when the display reads:

PROGRAM FUNCTIONS - LEVEL 1

The YES or NO should be flashing. Select YES to

prevent brewing if the water temperature is below the

set READY temperature. Select NO to permit brewing

at any water temperature.

When finished, press and release DONE. This

will exit this function screen and return to the MAIN

SCREEN on the display.

PROGRAMMING THE BREWER

The programming of the brewer is divided into two levels. There is one function in Level 1. All other functions

are accessed in Level 2.

The following function screens are in order of appearance. Each screen will have instructions on how to

access, and the procedures to program the various functions of the brewer.

IMPORTANT PROGRAMMING NOTES

- READ CAREFULLY -

To exit the programming mode at any time, press and release the ON/OFF switch located on the front switch

panel. The display will return to the MAIN SCREEN.

If none of the five programming switches are pressed within one minute during the setup of the brewer,

the programming of the function screen that is being set will be exited and the display will return to the MAIN
SCREEN.

Always remember to place a container and funnel under the sprayhead when operating the brewer during the

set-up of PULSE BREW, CALIBRATE FLOW and testing the brew and bypass valves in SERVICE TOOLS/TEST
OUTPUTS.

PROGRAM

ENABLE

DISABLE

PROGRAMMING

SWITCH

P2424

READY TO BREW

WATER TEMP: 205°

Press here

for NO

Press here

for DONE

Press here

for YES

BREW LOCKOUT?

NO

DONE

YES

35879.1 071405

Advertising