Bunn W/SMART FUNNEL S/N SNG0033000 & UP User Manual

Page 44

Advertising
background image

Page 44

Equipment will not operate.

Brew cycle will not start.

Automatic refill will not operate

or display shows FILL TIME TOO

LONG

1. No power or incorrect voltage.

1. No water

2. ON/OFF switch

3. Brew switch

4. Brew Valve

5. Electronic Control Board

1. No water

2. Water strainer

Measure the voltage at the terminal

block and confirm that it matches

the voltage specified on the brewer

data plate within +/- 10%.

Check plumbing and shut-off

valves

Test the ON/OFF switch. Refer to the

switch test procedures.

Test the BREW switch. Refer to the

switch test procedures.

Test the Brew valve. Refer to Testing

Individual Components.

Substitute a control board known to

be in good working order.

Check plumbing and shut-off

valves.

(A) Direction of flow arrow must be

pointing towards direction of water

flow.

(B) Remove the strainer and check

for obstructions. Clear or replace

TROUBLESHOOTING (cont.)

Troubleshooting Procedure

Problem

Possible Cause

35879.1 071405