TROUBLESHOOTING (cont.)

Problem

Possible Cause

Troubleshooting Procedures

Check the sensitivity setting. Refer

to the Refill function. If the left

three digit number is less than the

right number, the machine “thinks”

it is full and the refill valve should

be off. If the left number is larger

than the right, then the refill valve

will automatically be turned on to

fill the tank. The right number is

the threshold setting and can be

adjusted to compensate for extreme

water conditions: very pure, low

conductance water requires a higher

setting, while high mineral content,

high conductance water requires

a lower setting. Note that the left

number changes from a high value

when water is NOT touching the refill

probe to a low value when water IS

touching the probe. For best opera-

tion, the right number should be set

to a value midway between these low

and high numbers. Before changing

the setting, confirm that the refill

probe is free of scale buildup and

the connection to it is secure.

Substitute a control board known to

be in good working order.

Remove power from the brewer.

Press reset button on limit ther-

mostat. Then check for continuity

through it.

Remove power from the brewer.

Check for continuity through the

tank heaters.

1. Refill Probe or Sensitivity Set-

ting

2. Electronic Control Board

1. Limit Thermostat

CAUTION - Do not eliminate or

bypass limit thermostat. Use only

replacement part #23717.0001.

2. Tank Heaters

Water flows into tank continuously

with power applied to brewer.

Water will not heat or display shows

HEATING TIME TOO LONG