Information for Users in the U. S.

For units set at 115 V :

Use a UL Listed Cord Set consisting of a minimum 18 AWG, Type SVT or SJT three

conductor cord a maximum of 15-feet long and a parallel blade, grounding type attachment

plug rated 15 A, 125 V.

For units set at 230 V:

Use a UL Listed Cord Set consisting of a minimum 18 AWG, Type SVT or SJT three

conductor cord a maximum of 15-feet long and a tandem blade, grounding type attachment

plug rated 15 A, 250 V.

Information for Users outside the U.S.

For units set at 230 V:

Use a Cord Set consisting of a minimum 18 AWG cord and grounding type attachment plug

rated 15 A, 250 V. The Cord Set should have the appropriate safety approvals for the country

in which the equipment will be installed and / or be marked HAR.