Hale HFM User Manual

Page 11

Advertising
background image

Hale Model HFM

Front Mount Pump Operation Instructions

Pumping from Hydrant

1. Position chassis near hydrant and set parking brake. Shift truck transmission

to neutral position. Caution: Make sure that truck transmission shift quadrant

lock is used. Place wheel chocks in front and behind tires.

2. Attach one end of the suction hose to the hydrant and the other end to the

pump suction connection. Be sure the inlet strainer is installed and all drain

valves are closed.

3. Maintain engine idle speed, open hydrant, and slowly engage clutch in pump

transmission.

Caution: If clutch does not shift easily through its 180 degree travel,

do not force it, as this may cause serious damage to the pump
transmission. Instead, back the clutch off and re-engage it.

4. When discharge gauge registers pressure, open discharge line.

Note: It is not necessary to use primer when pumping from hydrant.

5. Accelerate engine and adjust discharge valves to obtain desired pressure and

volume.

6. When using soft suction hose between pump and hydrant, do not use

nozzles of larger capacity than the hydrant will supply.

Pumping from Booster Tank

1. Position chassis and set parking brake. Shift truck transmission to neutral

position. Caution: Make sure that truck transmission shift quadrant lock is

used. Place wheel chocks in front and behind tires.


2. Close all drain valves.

3. Maintain engine idle speed, open tank to pump supply line valve, and slowly

engage clutch in pump transmission.

Advertising