3 Installing the Air Locker

20

From the outside of the housing, assemble the small O-ring over

the top of the short length of seal housing tube protruding through
the bulkhead fitting.

While holding the seal housing tube into the bulkhead fitting, insert

the small drilled end of the center compression nut over the
extended tube as shown in the assembly diagram (Fig.14.), and
screw it into the bulkhead body, and lightly tighten.

NOTE : Be sure to insert the correct end of the center

compression nut into the bulkhead body. The thread
has been partially relieved on the bulkhead side of the
center compression nut to visually identify its
orientation. (Fig.14.)

Figure 14.





NOTE : Excessive tightening of the center compression nut is

not necessary to form a good seal around the tube
and may damage the O-ring, the seal housing tube, or
the threads of the compression nut.

NOTE : Make sure the seal housing tube is all of the way into

the center compression nut while you are tightening
it.