L.B. White I-5 Infraconic User Manual

Page 13

Advertising
background image

faucet pressure only, spray water against the cones to
wash out the build up of dust in the cones and the
venturi tube. Work your way around the entire cone
assembly.

3.

Run water down through the elbow and out through
combustion cones.

4.

Repeat steps 2 and 3 until water runs clean.

5.

Remove the plastic bag. Inspect the cones and
venturi tube to make sure these areas are clean.

6.

Return the heater to its original hanging position.

7.

Shake the heater vigorously to clear water off of the
combustion cones and to allow proper ignition of gas
at the inner cone.

8.

Install filter and relight the heater to dry out the cones
and the venturi tube.

B. FILTER

A. During continued use:

- Remove filter and shake off dust.
- Do not squeeze or tap filter while filter is installed

on heater. Doing so will cause dust to be blown

into venturi tube or combustion cones.

B. After continued use or before building repopulation:

- Remove filter and shake off dust.
- Use compressed air or water (standard faucet

pressure) to clean it.

- Do not use high pressure water, air, or a washing

machine. Filter material damage may occur.

- If water is used, squeeze out excess water from

filter before installation.

- Let filter dry before lighting heater.

13

Advertising