SAFETY GAS CONTROL VALVE AND BURNER ORIFICE

1. Disconnect the gas hose.

2. Remove the thermocouple from the safety control

valve.

3. Remove the filter (if necessary) and the screw on

filter holder.

4. Pull safety control valve from venturi tube.

5. Using a 6 mm hex nut driver, remove orifice and

clean if necessar y. When reinstalling, do not
overtighten as thread damage may occur.

FIG. 11

SCREW

ORIFICE

THERMOCOUPLE

1. Remove the thermocouple bracket nut from its

mounting stud. See Fig. 12.

2. Pull the thermocouple from its mounting location.

3. Remove thermocouple connector nut from pilot safety

gas control valve.

Note: The replacement thermocouple will ship with
factory installed bracket and a mounting nut.

FIG. 12

BRACKET

NUT

FILTER HOLDER