Installation layout, This not this – L.B. White I-5 Infraconic User Manual

Page 8

Advertising
background image

ATTENTION

Attach only steel cable or
chain to the heater’s hanging
chain. Do not use
combustible materials such
as ropes, lines, etc.

The installer must ensure
that the heater is hung so
control end of heater is
positioned 1º to 5º down
from horizontal after gas
supply hose is attached.This
allows proper venting of
heater and eliminates
potential heat damage to
dust filter.

Repositioning of chain within
hanging clips on heater may
be required.

Refer to illustrations.

8

9.

A qualified service agency must check for proper
operating gas pressures upon installation of the
heaters.

10.

Use the proper gas supply line to assure proper
functioning of the heaters. Typically, 3/4 in. ID black
iron pipe is used to supply gas to the inlet of the zone
control panel with 1/2 in. ID black iron pipe used to
convey the gas to the heaters. However, always consult
your fuel gas supplier, or the L. B. White Co., Inc. for
proper line sizing and installation.

11. Infraconic heaters require a regulated gas supply to the

gas inlet. Exceeding the gas inlet pressure rating can
result in poor performance and unreliable operation.
Refer to page 4 of this manual for information on gas
pressures relating to specific models.

12.

The heater is designed for either L.P. vapor with-drawal
or natural gas, depending on model number. Do not
u s e t h i s h e a te r i n a n L P G l i qu i d w i t h d r awa l
system. Do not permit LPG in liquid form to enter the
heater at any time.

13.

T h e c o r ro s i ve a t m o s p h e r e p r e s e n t i n a n i m a l
confinement buildings can cause component failure or
heater malfunction. The heater should be periodically
i n s p e c te d a n d c l e a n e d i n a c c o rd a n c e w i t h t h e
Maintenance and Cleaning Instructions in this manual.
Make sure that livestock is protected by a back up
alarm system that limits high and low temperatures and
also activates appropriate alarms.

14.

Take time to understand how to operate and maintain
the heater using the owner’s manual. Make sure you
know how to shut off the gas supply to the building and
to the individual heaters. Contact your gas supplier if
you have any questions.

15.

Any defects found in performing any of the service
procedures must be eliminated and defective parts
replaced immediately. Retest the heater before placing
it back into service.

INSTALLATION LAYOUT

FOR SAFE CLEARANCES

I17 & I34 - 3 FT. MINIMUM

BROODER TOP TO CEILING

POSITION THE GAS HOSE AND ELECTRICAL POWER CORD
OUTSIDE OF THE HOT ZONE DIRECTLY ABOVE THE HEATER.
POSITION THE GAS HOSE AND POWER CORD TO AVOID
ANY OPPORTUNITY FOR CONTACT WITH THE HOT CANOPY
SURFACE OF THE HEATER.

MINIMUM 3 FT. CLEARANCE

TO COMBUSTIBLES

FLOOR

I17 - 3.5 FT. MINIMUM
I34 - 4.5 FT. MINIMUM

POINT OF COMBUSTION

CONE TO FLOOR

HANG THE HEATER WITH THE
CONTROL END 1 TO 5 DEGREES DOWN
FROM HORIZONTAL (SEE BELOW)

CONTROL PANEL

GAS PIPING

2.5 FT. MINIMUM

BROODER TOP TO CEILING

3.0 FT. MINIMUM

POINT OF COMBUSTION

CONE TO FLOOR

POSITION THE GAS HOSE OUTSIDE OF THE HOT ZONE
DIRECTLY ABOVE THE HEATER. POSITION THE GAS HOSE TO
AVOID ANY OPPORTUNITY FOR CONTACT WITH THE HOT
CANOPY SURFACE OF THE HEATER.

I5-001.prt

U
UUUUU U

U

U

U U
U

U U U
U U U U

HEATER CHAIN

THIS

NOT THIS

STEEL CHAIN OR
CABLE

HANGING CLIP

HANGING CLIP

CONTROL END
OF HEATER

CONTROL END OF HEATER MUST BE 1-5 DEGREES DOWN FROM HORIZONTAL