Troubleshooting
A - Introduction

Before calling your machine supplier or Service Department, please check whether you can solve the problem
yourself. If you cannot, then call the Servic e Department for advic e. Have the model number and serial
number at hand (these can be found on the silver CE sticker at the service panel at the back of the m achine).
Use the Problem Solving chart below to judge whether you c an solve a problem yourself or not. The tool
symbol (

) means you cannot solve the problem yourself and the Service Departm ent must be called. On no

occasion remove side panels yourself, this may only be done by trained service personnel. This c hart does not
include any of the malfunctions which are reported in an error message by the software. In the event of a
malfunction, these messages and possible solutions are displayed on the m onitor.

Attention! MOVING PARTS CAN CAUSE INJURY. Always turn off power
before accessing moving parts.

B - Problem solving

Symptoom

Cause

Action

Nozzle leaks through the outlet
opening

Air bubble in pump

Prime the pump

Pump is defective

Replace pump

Canister connection leaks
around the suction point

Worn O-ring(s)

Replace O-ring(s)

Air is being fed together with
the paste

Air bubble in the pump

Prime the pump

Canister is empty

Refill canister

(New) software is not working

Program not correctly booted

Reboot computer & software

Software incorrectly installed

Reinstall software

No power from power unit

Not connected to power grid

Check power cables

Fuse blown

Remove plug from socket, replac e
fuse

Colours are difficult to
reproduce

Mechanisms are dirty

Clean and oil

Quality fluctuations in paste supplied

Contact paste supplier

One or more pastes have thickened

Replace paste(s)

Poor monitor picture, or no
picture

Monitor is switched off

Switch monitor on

Loose cable(s)

Check cables

Picture set too dark

Adjust picture correctly

Monitor malfunctioning

Keyboard is not working

Loose cable(s)

Check cables

Windows Regional setting is inc orrect Check Windows software manual

Defective cable(s)

Keyboard is defective

Stirrer is not rotating

Top lid not closed properly

Close top lid

Timer setting incorrect

Use the software to set the
timer correctly

Loose cable

Check cable

Defective cable

Defective motor

Advertising