J.p.instruments, Fuel flow installation manual – J.P. Instruments EDM 730 Fuel Flow Installation Manual User Manual

Page 14

Advertising
background image

J.P.Instruments

Fuel Flow Installation Manual

Report # 503

for EGT-701 with Fuel Flow Option Page 14 of 14

Rev B : Date 03/14/97






10.. Installing the Fuel Flow Differential Module FFDM-I and the FFDM-2:

If your engine is equipped with a fuel return line from the carburetor back to the fuel tank, install the FFDM-1 or
FFDM-2 in the aircraft as outlined below (see sheet one ). Otherwise, omit this step.

a) Connect the connector to the FFDM-I, -2

b) Install the FFDM-1, -2 under the instrument panel using two tie wraps on each end of the module to support it to

a wire bundle or bracket.


c) Only required on the FFDM-1. Route and connect the 3' red power lead to the 12 or 24 volt bus via a 1 amp

fuse. Route and connect the 3' black ground lead to the same ground used for the EGT-701(),with Fuel Flow
option.


d) Route and connect the 6' red, black and white leads marked "Feed" to the flow transducer installed in the fuel

line from the fuel pump to the carburetor.


e) Route and connect the 6' red, black and white leads marked "Return" to the flow transducer installed in the

return fuel line from the carburetor to the fuel tank.


f) Connect the red, black and white leads to the same color 6' leads from the EGT-701(),with Fuel Flow option.

Any excess wires can be rolled up and tie wrapped under the instrument panel. Tie wrap these wires so they do not
obstruct the freedom of travel of any controls.

J.P.INSTRUMENTS

PO Box 7033
Huntington Beach CA 92646

Title:

FFDM-1 Interconnect Wiring Diagram

Drawing No.

700920

Date

02/14/97

Drawn

Approved

Sheet

2 of 2