background image

For Your Safe Flight

Page 17

The STEP and LF buttons control all functions of the EDM. The term
tap denotes pressing a button momentarily. The term hold denotes
pressing and holding a button for five seconds or longer.

STEP Button - Primary functions

 In the Automatic mode, tapping the STEP button will change to

the Manual mode. Subsequent taps of the STEP button will
display the next parameters in the sequence.

 In the LeanFind mode tapping the STEP button will terminate

the LeanFind mode and change to the Automatic mode.

STEP Button - Secondary functions

 In the Manual mode, holding the STEP button will display the

previous parameters in the sequence (rapidly backwards).

 In the Pilot Program Mode, tapping the STEP button will

generally advance to the next item in the list.

 When an alarm is displayed, tapping the STEP button will

prevent that alarm from appearing for the next ten minutes.

 When an alarm is displayed, holding the STEP button until the

word OFF appears, prevents that alarm from appearing for the
remainder of the flight.

LF Button - Primary functions

 In Automatic or Manual modes, tapping the LF button will

change to the LeanFind mode.

 In the LeanFind mode, holding the LF button after peak EGT is

found will display peak EGT.

 In Automatic or Manual modes, holding the LF button for three

seconds will toggle between Percentage and Normalize views.