FAA Approved Installation Manual for the EDM-960 system Report No 909

Primary Engine Data Management System Page 24 of 46 Rev D

Date 2-6-2014


3. Tap USER when you see ‘Do you want to restore user table?’ (Note: tapping FACTORY causes the fuel table

stored on the Key Card to over-write any previous user entries in the fuel table. Use FACTORY if you want to start from
the original factory default).

4. Tap POINTS when you see ‘Do you want to edit the table?’.

5. You see ‘Points in LEFT’, the current calibration points for the LEFT tank.

6. Tap/hold VALUE to change to the desired number of calibration points for this tank (2 to 5). Each Tank can have a

different set of calibration points. So 5 points for Main and 2 points for Aux.

7. Tap TANK to select the next active tank and repeat previous step. Continue until all tanks ‘points’ have been set.