FAA Approved Installation Manual for the EDM-960 system Report No 909

Primary Engine Data Management System Page 5 of 46 Rev D

Date 2-6-2014


Alarm hierarchy

When a measurement limit is reached, the pilot can momentarily tap the STEP button on the EDM-960 instrument to
extinguish the particular flashing alarm acronyms. If another measurement has also reached its limit, that label will
then begin to flash. The pilot should continue to monitor the affected parameters (just as he would using a
conventional analog display that had reached a limit). The bar graph functions of CHT, EGT, and TIT remain displayed
for easy reference should one of these limits be reached.

1. OILP_LO.
2. FP_LO.
3. OILT_HI.
4. CHT.
5. TIT.

6. FLVL.
7. REM.
8. FP_HI.
9. MAP.
10. DIF.

11. CLD.
12. RPM.
13. OILT_LO.
14. VOLTS.
15. OILP_HI.

16. AMPS.
17. CDT.
18. RES.
19. EGT.
20. Fuel Flow.

6. Dimming
Automatic dimming is provided to dim both the panel display and the remote alarm display, RAD. Dimming can also be
accomplished manually to change the Automatic setting. Tapping the third right button will bring up the Dim/Bright
menu making the 3 and 4

th

button Dim or Bright in % Bright. Continuously holding this button increases brightness

mode display.

Each EDM-950 has four mounting holes to mount to the avionics equipment rack or to the cold side of the firewall.
The data ports are then connected to the display unit via a harness terminating at the EDM-930 display with a 25 pin
D-Sub connector.

Remote Alarm Display PN
790749

DAU EDM-950 P/N 790000-B