J.P. Instruments EDM 960 Twin Primary Installation Manual User Manual

Page 32

Advertising
background image

FAA Approved Installation Manual for the EDM-960 system Report No 909

Primary Engine Data Management System Page 32 of 46 Rev D

Date 2-6-2014

Bendix 1200………………………….P/N 420807

35.13 Components Parts list for RPM sensor P/N depends on Magneto make and model

Bendix magneto -20,120…………..P/N 420815-2
Slick magneto 4000 or 6000………P/N 420815-1
Bendix dual ………………………...P/N 420808

36. Weight and Balance Data

DAU PN 790000-B EDM-950

1.8 Lbs

Indicator PN 790000-C-120, EDM-930 incl. 2 RADs

2.0 Lbs

EGT / TIT / CDT / IAT / OAT probe

2.0 oz. each / 0.125 lbs

CHT / Oil Temperature probe

1.5 oz. each / 0.094 lbs

4/6 Cylinder Harness 8 ft.

14.0 oz. each / 0.88 lbs

RPM and MAP

5.0 oz / 0.42 lbs

Fuel Pressure Sender

5.0 oz / 0.42 lbs

Oil Pressure Sender

5.0 oz / 0.42 lbs

Harness each

1.0 Lbs

37. Pilot Programming

Refer to the Pilots Guide for specific Pilot Programming details. Basically to start the Pilot Program procedure,
simultaneously hold the STEP and LF buttons for five seconds. You will see the word PROGRAM for two seconds and
then the example sequence shown in the chart below.

Tap the STEP button to advance to the next item in the list. Hold the STEP button to step back to the previous item.
Tap the LF button to select alternate values of that item. Simultaneously hold both STEP and LF to exit.

STEP

advances

next item

LF

sequen

ces

through

these

values


Comments

PROGRAM

Stays on for two seconds.

FUEL N

FILL?
N

Tap LF to change fuel status. Exits program mode when done.

RATE 4

0 … 9

Index rate (pause time in seconds) in the Automatic Mode. 0 disables the Automatic
Mode.

OAT F

OAT
F

OAT
C

To calibrate the OAT

10°, hold both the STEP and LF buttons simultaneously for five

seconds, which will proceed to the next step. Otherwise the next step will be skipped.

OAT

0

OAT-I0

OAT

I0

This step will be normally be skipped.

Adjust the indicated temperature up or down by up to 10°. For example, OAT

3 adjust

the OAT 3° higher.

EGT I?N

EGT
I?N

EGT
ICY

Y—Yes—sets the digital display to one-degree resolution; N—No—sets 10°. (10°
resolution is easier to interpret the Get’s.)

Advertising