AEM 30-5140M Analog Oil Transmission Water Temperature Metric Gauge User Manual

Page 2

Advertising
background image

Page 2

INSTALLATION

1. Disconnect the negative battery cable.
2. Secure the gauge in a 2 1/16

th

” (52MM) mounting hole with the supplied bracket.

3. Plug the 8-wire power harness into the mating connector on the back of the

gauge and connect the wires as shown in Figure 1. Note: the locating tabs on
the side of the connector should be nearest the center of the gauge.

4. Thread the sensor into a suitable temperature

port that has 1/8” NPT female

threads. Note: a small amount of thread sealant may be used.

5. Connect the sensor to the gauge using the 2-wire sensor cable. The single-row,

3-position connector connects to the back of the gauge. The locating tabs on the
connector should be nearest the center of the gauge.

6. Reconnect the negative battery cable.

RED (Power) - Connect to a constant 12 volt power source utilizing a 5A fuse.

BLACK (Ground)

– Connect to a clean power ground.


PINK (Switched Power)

– Connect to a switched 12 volt power source utilizing a 5A

fuse.

GREY (Light Intensity) - Connect to instrument lighting circuit supply voltage.

*WHITE (Analog Output) - Connect to Analog + Input.

*BROWN (Analog Ground) - Connect to Analog

– input. (Must be connected if Analog +

is used)

*optional

– only needed if using the available differential analog output


Wiring notes:

RED - When wired as shown above, the gauge will park the needle against the

needle stop upon powering down. Alternatively, the RED wire can be connected to the
same location as the PINK wire. With the RED wire and the PINK wire connected to the
same switched power, the needle will remain at its current position upon powering
down. For both power connection methods, the needle will rotate to the parked position
before rotating to the value of the current operating condition upon powering up.

GREY

– The GREY wire is used to control the lighting intensity of the gauge.

Maximum lighting intensity is achieved when the GREY wire is connected to 12 volts.
Minimum lighting intensity is achieved when the GREY wire is not connected. The
instrumentation illumination on many vehicles is controlled by varying the supply voltage
to the instrument panel lights. When the GREY wire is connected to the instrument
panel supply voltage, the intensity of the gauge is controlled by the dimmer switch on
the dash.

WHITE

– The WHITE wire should be connected to the Analog + input on the

AEM EMS or the analog + input on a similar device.

BROWN

– The BROWN wire should be connected to the Analog – input. If the

EMS or similar device does not have a

– input, the BROWN wire should be connected

to a sensor ground. If no sensor ground is available, the BROWN wire should be
connected to a power ground. Note: The BROWN wire must be connected in order
to get correct readings from the analog output.