2GIG GB1-345 Glass Break User Manual

Glass break detector, Install instructions, Box contents

Advertising
background image

GLASS BREAK DETECTOR

INSTALL INSTRUCTIONS

The Glass Break Detector is a fully supervised, tamper‐protected, ceiling 
or wall‐mounted unit with 15 feet maximum detection range, 
360°maximum horizontal sensing angle, and dual‐stage glass break 
detection.

Box Contents

Mounting base

Sensor

2 Lithium batteries

3 Phillips head screws

3 Wall anchors (plastic)

Programming

The following steps describe general guidelines for programming 
(learning) the Glass Break Detector into the Control Panel. Scroll between 
op ons using the ← and → arrows. Move to the previous or next prompt 
by pressing the ↑ and ↓ arrows. 
1

Select RF sensor # (01 to 48). Assign the Glass Break Detector to a 
new zone.

2

Select RF sensor type:
(03) glass break

3

Select RF sensor equipment code. Enter 5853 for the Glass Break 
Detector.

4

Select RF equipment type.
(1) contact

5

Enter RF sensor serial number (7 digits).
Manual Entry: Type in the last 7 digits of the TX ID that is found 
outside of the box or on the back of the device.
Auto Entry: With the panel in Learn‐in mode, (press Shift then Learn
press the tamper switch. The correct TX ID should appear. Accept the 
correct TX ID by pressing ok.
Remember to press the ↓ arrow to continue going through the 
system configuration prompts.

6

Select RF sensor equipment age (0 to 1).
(0) new (product is new)
(1) existing (product already exists)

7

Select RF sensor loop number (1 to 3).

8

Select RF Sensor dialer delay (0 to 1)
(0) disabled

9

Construct RF sensor voice descriptor. Press Insert then press any 
number between 002 and 255 to add a word. Repeat this for each 
word. For example, if you want to name this Glass Break Detector as 
the “master bedroom,” press Insert then press 140 for master. Press 
Insert then press 024 for bedroom.

10

Select RF sensor reports (0 to 1).
(0) disabled (Glass Break Detector does NOT report to central station)
(1) enabled (Glass Break Detector reports to central station)

11

Select RF sensor supervised (0 to 1)
(0) disabled (detector does not report loss of supervision/low battery)
(1) enabled (detector reports loss of supervision/low battery)

12

Select RF sensor chime (0 to 13).
(0) disabled (panel will NOT chime when Glass Break Detector is 
activated)
(1‐13) enabled (selects a voice and chime to sound on the panel when 
the Glass Break Detector is activated)

13

To program another sensor click next.

14

To exit programming, click skip then end and exit. Upon exit, the 
panel takes several seconds to reboot.

Testing

Walk Test

1

Push the test button for 2 seconds 
and then release it. The red LED 
appears while the button is pressed.

2

The green LED will blink once to 
indicate that the unit is in auto test 
mode for 90 seconds.

3

Activate a glass break simulator in the 
area of the window or windows that 
you are attempting to protect with 
the glass break detector. The Glass Break Detector should first 
acknowledge the detection of a thud sound by illuminating the green 
LED and then illuminate the red LED when the unit detects the crash 
portion of the glass breaking sound.

RF Test

Push and hold the test button for 5 seconds and then release it. The 
red LED appears while the button is pressed. The green LED will blink 
twice to indicate that the unit is in RF test mode for 90 seconds.

NOTE:

Perform a system test (per the User Guide) at least once a 

year.

Glass Type/Thickness

Minimum size for all glass types is 11” x 11” (28cm x 28cm) square; glass 
must be framed in the wall of the room or mounted in a barrier of 36”
(.9 m).

† Sealed insula ng glass types are protected only if both plates of glass 
are broken.

TIP:

When wall mounted, the Glass Break Detector is designed to 

provide coverage on the opposite or adjacent windows and not 
on windows on the same wall as the Glass Break Detector.

Installation

1

Hold the 2GIG‐GB1‐345 Glass Break 
Detector unit upside down and twist the 
base counter clockwise to remove it.

2

Install recommended batteries making 
sure to observe the correct polarity.

3

Wait 5 seconds for the power up delay.

4

Enter the programming mode for a 
wireless device on the 2GIG alarm 
control panel.

5

Learn the Glass Break Detector into the 
Control Panel by pressing and holding the tamper switch for 2 
seconds.

Type

Minimum to Maximum Thickness

Plate

1/8 in. to 1/4 in. (3.2 mm to 6.4 mm)

Tempered

1/8 in. to 1/4 in. (3.2 mm to 6.4 mm)

Sealed Insula ng†

1/8 in. to 1/4 in. (3.2 mm to 6.4 mm)

FCC ID: WDQ‐GB1345

Industry Canada ID: 7794A‐GB1345

Advertising