GETTING STARTED

To enter the control panel’s System Configuration module to

program sensor zones and modify settings:

1.

At Home screen, tap logo in lower-right corner.

Enter:

Master Installer Code.

Tap:

System Configuration.

Or

2.

At Home screen:

Tap:

Security > Menu > Toolbox.

Enter:

Master Installer Code.

Tap: 

Installer Toolbox > System Configuration

To navigate through questions and options in the System Configuration

module:

Tap

or

to scroll between options on the active screen.

Tap

or

to move to the previous or next screen’s question.

For step-by-step programming information, see the installation

instructions for the peripheral device or the control panel’s

Installation and Programming Guide from

dealer.2gig.com

.

Q1 WIRELESS ZONE PROGRAMMING

(Q1) SELECT RF SENSOR # (01 to 48)

Select:

RF Sensor # (01 to 48)

to select the desired zone option. Then

tap

Select:

RF Sensor # Type

to select type. Then tap

Select:

RF Sensor Equipment Code

to select code (see Equipment

Codes on page 4). Then tap

Enter:

RF Sensor # Serial Number (7 Digits) Enter the serial number or

place the control panel into learning mode by tapping Shift >

Learn and then trip the sensor to transmit its serial number to

the control panel.

Select:

RF Sensor # Equipment Age

to select (1) New or (2) Existing

Then tap

Select:

RF Sensor # Loop Number

to select (1) 1, (2) 2, or (3) 3:

1-Use Loop 1 for all 2GIG products (except as noted in loops

below)

2-Thin door/window contact using internal switch

3-Flood/freeze sensors. Then tap

Select:

RF Sensor # Dialer Delay (0 to 1)

until desired option

Construct:

RF Sensor # Voice Descriptor Tap Insert. Then tap

to scroll

the available words or enter the 3-digit code associated with

the desired word. Tap Insert again before adding another word.

There is a five (5) word maximum. See Voice Descriptors on

page 4. Then tap

Select:

Select RF Sensor # Reports (0 to 1)

to select (1) Enabled or (2)

Disabled. Then tap

Select:

Select RF Sensor # Supervised (0 to 1)

to select (1) Enabled or

(2) Disabled. Then tap

Select:

Sensor Chime

to select chime. Then tap

SUMMARY OF RF SENSOR # SCREEN

The Summary shows the settings for each sensor. Tap Edit Next to add the

next RF sensor, or tap Edit Current to reconfigure the current RF sensor. Tap

Q2 WIRED SENSOR PROGRAMMING

If no wired sensor programming is needed, tap Skip to go to Q3 Key Fob

Programming.
(Q2) ENTER WIRED SENSOR # (1 thru 2)

Select:

Sensor (Zone) Type

until desired option

Select:

Equipment Age (New/Existing)

until desired option

Select:

Normal State

until desired option

(0) Not Used, (1) Normally Closed, (2) Normally Open, or (3)

Mixed with no EOL. Then tap

Select:

Dialer Delay (Enabled/Disabled)

until desired option

Construct:

RF Sensor # Voice Descriptor Tap Insert. Then tap

to scroll the

available words or enter the 3-digit code associated with the

desired word. Tap Insert again before adding another word.

There is a five (5) word maximum. See Voice Descriptors on

page 4. Then tap

Select:

Sensor Reports (Enabled/Disabled)

until desired option

Select:

Sensor Chime

until desired option

SUMMARY OF WIRED SENSOR # SCREEN

The Summary shows the settings for each sensor. Tap Edit Next to add the

next wired sensor, or tap Edit Current to reconfigure the current wired sensor.

Tap Skip to move to Q3 Keyfob Programming.

Q3 KEY FOB PROGRAMMING

If no key fob programming is needed, tap Skip to go to Q4 Keypad Programming.
(Q3) SELECT FOB # (1 to 8)

Select:

Fob <#> Used (0 to 1)

to select (1) Disabled or (2) Enabled. Then tap

Select:

Fob <#> Equipment Code

to select code (see Equipment Codes on

page 4). Then tap

Enter:

Fob <#> Serial Number (7-Digits) Enter the serial number manually (7

digits) or place the panel into learning mode by tapping Shift > Learn

and then tap the Armed Away button on the key fob until the LED

illuminates and the sensor transmits the serial number.

Select:

Fob # Equipment Age (0 to 1)

to select (0) New or (1) Existing. Then

tap

Select:

Fob # Emergency Key (0 to 4)

to select (0) Disabled, (1) Auxiliary

Alarm, (2) Audible Alarm, (3) Silent Panic, or (4) Fire. Then tap

Select:

Fob Can Disarm (Enabled/Disabled)

until desired option

Construct:

RF Sensor # Voice Descriptor Tap Insert. Then tap

to scroll the

available words or enter the 3-digit code associated with the desired

word. Tap Insert again before adding another word. There is a five (5)

word maximum. See Voice Descriptors on page 4. Then tap

Select:

Fob # Arm No Delay (0 to 1)

to select (0) Disabled or (1) Enabled.

Then tap

Select:

Fob # Key # Output (0 to 2)

to select (0) Disabled, (1) Toggle

Output, or (2) Momentary Output. Then tap

SUMMARY OF FOB # SCREEN

The Summary shows the settings for each sensor. Tap Edit Next to add the next

keyfob, or tap Edit Current to reconfigure the current keyfob. Tap Skip to move to Q4

Keypad Programming.

FIELD PROGRAMMING FOR COMMUNICATION

(Q13) SELECT TWO-WAY VOICE (0 TO 2)

Tap:

Go To. Then enter 13 to select a two-way voice option.

Select:

Two-Way Voice (0 to 2)

to select (1) Stay On Line or (2) Stay On Line,

Including Fire and CO Alarms. Then tap

TO SETUP CELL PRIMARY: (Q8) SELECT DIALER (0 TO 1)

Tap:

Go To. Then enter 08 to select the dialer.

Select:

Dialer (0 to 1)

to select (0) Disabled. Then tap

Tap:

Go To. Then enter 63 to select a phone fail detect option.

Select:

Phone Fail Detect (0 to 1)

to select (0) Disabled. Then tap

TO SETUP POTS PRIMARY: (Q8) SELECT DIALER (0 TO 1)

Tap:

Go To. Then enter 08 to select the dialer.

Select:

Dialer (0 to 1)

to select (1) Enabled. Then tap

Tap:

Go To. Then enter 63 to select phone fail detect.

Select:

Phone Fail Detect (0 to 1)

to select (1) Enabled. Then tap

Tap:

Go To. Then enter 11 to enter the CS Phone Number.

Select:

CS #1 Phone Number (0-25 Digits) Enter the phone number. Then tap

Tap:

Go To. Then enter 12 to enter the CS Account Number.

Select:

CS #1 Account Number (4 Digits) Enter the account number. Then tap

77-000010-001 Rev D

For technical support in the USA and Canada:

855-2GIG-TECH (855-244-4832)

or visit the

2GIG dealer site at

dealer.2gig.com

, or email us at

[email protected]

.

For technical support outside of the USA and Canada, contact your regional distributor.

Copyright © 2014 Linear LLC.

Quick Programming Guide

Control Panel Firmware Version 1.13

Q4 KEYPAD PROGRAMMING

If no keypad programming is needed, tap Skip to go to Field Programming for

Communication.
(Q4) SELECT RF KEYPAD # (1 to 4)

Select:

Keypad RF Keypad # (1 to 4)

to select desired keypad number. Then

tap

Select:

RF Keypad # Used (0 to 1)

to select (0) Disabled or (1) Enabled.

Then tap

Select:

RF Keypad # Equipment Code

to select code (see Equipment Codes

on page 4). Then tap

If using a Wireless Keypad (2GIG-PAD1)

Enter:

RF Keypad 1 Serial Number (7 Digits)

Enter the serial number or

place the control panel into learning mode by tapping Shift > Learn

and then trip the sensor to transmit its serial number to the control

panel.

If using a Wireless Touch Screen Keypad (2GIG-TS1*)—*Not available in all

regions

Select:

RF Keypad # Keypad ID (Read-Only) Tap the Learn button. Then go to

the TS1 and tap the Pair WIth Panel button. When the learning

operation succeeds, tap OK on both the panel and TS1.

Select:

RF Keypad 1 Equipment Age (0 to 1)

to select (0) New or (1)

Existing. Then tap

Select:

RF Keypad # Emergency Keys (0 to 1)

to select (0) Disabled or (1)

Enabled. Then tap

Construct:

RF Sensor # Voice Descriptor Tap Insert. Then tap

to scroll the

available words or enter the 3-digit code associated with the desired

word. Tap Insert again before adding another word. There is a five (5)

word maximum. See Voice Descriptors on page 4. Then tap

SUMMARY OF RF KEYPAD # SCREEN

The Summary shows the settings for each sensor. Edit Next to add the next keypad,

Edit Current to reconfigure current keypad. Tap Skip to move to Field Programming

for Communication.