RESETTING THE SENSOR

Before programming the image sensor into a new network,

you must reset it as follows:
1. Insert a paperclip into the hole on the front of the

sensor to access the Reset button.

2. Press and hold the Reset button for three (3) seconds.

This power cycles the sensor.

3. Hold down the Reset button for 10 seconds. When the

LED begins flashing, the sensor is reset and is removed

from the existing network.

NOTE: If the image sensor is not communicating with its

network, you can use the Reset button to clear the sensor

from that network. If the sensor is still communicating with

its network, clear sensor by deleting it from the control

panel.

SENSOR RESET HOLE

WIFI TO THE ON-SITE ROUTER (WPS)

1. If the on-site router supports WiFi Protected Setup (WPS), press

the WPS button (A) until the routher enters WPS mode (the

indicators will differ slightly from router to router). This gives the

routher the ability to “listen” for a new WPS device.

2. Press the WPS button (A) on the camera. This action causes the

camera to announce itself to the router as a WPS device. While the

camera is in WPS mode, the LED on the camera blinks YELLOW.

3. Do not press any buttons on the camera until its LED illuminates

GREEN, which indicates the camera has successfully connected to the

network.

4. From the Alarm.com website add and configure the camera.

WIFI TO THE ON-SITE ROUTER

1. Connect the camera directly to the router using an ethernet cable.
2. From the Alarm.com website add and configure the camera to

connect using WiFi.

3. Disconnect the power cable from the camera.

4. Disconnect the Ethernet cable from the camera. A WiFi connection

will be established.

ETHERNET TO THE ROUTER

1. Connect the camera directly to the router using an Ethernet cable.
2. From the Alarm.com website add and configure the camera.
NOTE: Access points and cellular “hot spots” will not work with the

HD100 Camera. You must have a router installed in the home.

LED

WPS

RESET

LED States

State

LED Pattern

Normal Operation

Solid Green

Connectivity Problems

Blinking Red

WPS Transaction in Progress

Blinking Yellow

Booting

Solid Yellow

77-000010-001 Rev D

For technical support in the USA and Canada:

855-2GIG-TECH (855-244-4832)

or visit the

2GIG dealer site at

dealer.2gig.com

, or email us at

[email protected]

.

For technical support outside of the USA and Canada, contact your regional distributor.

Copyright © 2014 Linear LLC.

1.

CREATE AN ALARM.COM CUSTOMER ACCOUNT

. When creating an

account on the Alarm .com dealer site, enter the serial number for the

2GIG CDMA Cell Radio Module (2GIG-GC CDMA).

2.

VERIFY THE CELL RADIO AND TRANSCEIVER INSTALLATION

. Ensure that

the 2GIG-GC CDMA and 2GIG-XCVR2 radio are properly installed and

connected inside the control panel. The firmware version must be v1.10

(or higher).

3.

REGISTER MODULE AND TEST COMMUNICATIONS

. Power up the panel

and initiate a cell phone test to ensure the communication module is

properly installed and communicating with Alarm.com.

4.

PROGRAM THE SENSOR INTO THE CONTROL PANEL

. Enter the control

panel’s System Configuration module (see page 1).

Select:

RF Sensor # (01 to 48)

to select the desired zone option. Then

tap

Select:

RF Sensor # Type

to select (04) Interior Follower, (10) Interior

with Delay, or (3) No Response Type. Then tap

Select:

RF Sensor # Equipment Type

to select (1) Motion. Then tap

Select:

RF Sensor Equipment Code

to select (9999) Alarm.com Image

Sensor. Then tap

Enter:

RF Sensor # Serial Number (Read Only) Use the MAC address

(must be learned into the panel).

Select:

RF Sensor # Equipment Age (0 to 1)

to select (0) New or (1)

Existing. Then tap

Select:

RF Sensor # Loop Number (0 to 3)

to select (1) 1. Then tap

Select:

RF Sensor # Dialer Delay (0 to 1)

to select (0) Disabled. Then

tap

Construct:

RF Sensor # Voice Descriptor

Tap Insert

. Then tap

to scroll through the available words or

enter the 3-digit code associated with the desired word. See

Voice Descriptors on page 4. Then tap

Select:

RF Sensor # Reports (0 to 1)

to select (1) Enabled. Then tap

Select:

RF Sensor # Supervised (0 to 1)

to select (1) Enabled. Then

tap

Select:

RF Sensor # Chime (00 to 13)

to select (00) Disabled (A chime

is not recommended). Then tap

Continue by programming the next image sensor or tap Skip, then End,

and then make sure a checkmark appears in the Save Changes box and

tap Exit.

6. Perform a cell phone test to ensure that the updated equipment list is

sent to Alarm.com.

REQUIREMENTS

Go!Control Panel (Firmware Version 1.10 or higher)

2GIG-Cell Radio Module

2GIG Transceiver Module (2GIG-XCVR2-345)

Installing the Indoor HD Camera (2GIG-CAM-HD100)*

Control Panel Firmware Version 1.13

*not available in all regions

RESET TO DEFAULTS

Press and hold button (B) until the camera LED

changes to yellow (approximately 10 seconds).

When the camera LED changes to yellow, release

button (B) to reset the camera to factory defaults.

For best results, program one (1) image sensor into the

panel at a time and insert the batteries (to trip the sensor)

after placing the panel into learning mode.

Installing the Image Sensor (2GIG-IMAGE1)*

Control Panel Firmware Version 1.13

*not available in all regions

Advertising