Boot rom tests, Ethernet controller tests, Hard drive tests – Apple Server Diagnostics User Manual

Page 45: Memory tests

Advertising
background image

Appendix

Server Diagnostics Test Reference

45

Boot ROM Tests

Test

Estimated completion time

Description

Boot ROM Checksum

1 second

Verifies the Boot ROM
checksum.

Boot ROM FW GUID MAC Addr
Checksum

1 second

Verifies the Boot ROM FireWire
GUID MAC address checksum.

Ethernet Controller Tests

The availability of Ethernet controller tests depends on the Enternet controller installed
in the server.

Test

Estimated completion time

Description

MAC Address Verification

1 second

Verifies MAC address isn’t all FFs
or 00s.

PCI-E 1 LinkWidth Verification

1 second

Verifies PCI link width is 1.

PCI-E 2 LinkWidth Verification

1 second

Verifies PCI link width is 2.

PCI-E 4 LinkWidth Verification

1 second

Verifies PCI link width is 4.

PCI-E 2.5G Link Speed
Verification

1 second

Verifies PCI link speed is 2.5G.

Hard Drive Tests

When Server Diagnostics EFI starts, it performs a hardware existence test. All hard
drives found during this test can be tested individually using hard drive tests.

Test

Estimated completion time

Description

Full Read

2 hours for an 500 GB drive;
3 hours for a 1 TB drive

Performs a DMA full-read scan
at 1250 RPM. This checks the
entire hard drive for slow-read
failures.

Abbreviated Read

2 minutes

Performs a DMA scan at 1250
RPM. This checks the first 10 GB
of the hard drive for slow-read
failures.

Memory Tests

All memory tests are listed under Memory. These tests are described here.

An ECC error count test is automatically run after these tests complete.

Simple Memory Tests

Simple memory tests test the first 2.5 GB of memory. To test all memory, run extended
memory tests.

Advertising