9.3.4 Replacing the spreader arm, spreader tips, protective cover and handle

of the spreader

Components to be

replaced

Required work steps

Handle

1., 2. and 8.

Plug-on tips

1., 3. and 8.

Protective cover

1. - 7. and 8.

Lever links

1. - 6. and 8.

Spreader arms

1. - 7. and 8.

Work steps:

1. First of all, carefully clean the rescue equipment. Now switch off the device and remove

the battery or unplug the power supply from the device.

2. Remove the fi xing screws "A" and

remove the handle "B". The handle of
SP 310 E2 is mounted with through bolts
and nuts.

A

B

H

G

J

G

H

J

3. To remove the plug-on tips "G", you must simultaneously press in the buttons "J" on both

sides of a spreader arm "H" and pull the plug tips forwards until they come off.