4.4 Hydraulic supply

A LUKAS motor pump or hand pump only may be used to drive the equipment.

If the pump unit is a different make, you must make sure that it complies with LUKAS

specifications, otherwise potential dangers may occur which are not the responsibility of

LUKAS. Ensure in particular that the authorised operating pressure for LUKAS equipment

is not exceeded.

REMARK:

Before you use pumps from a different manufacturer, you must contact LUKAS

or an authorised dealer.

The pump unit and rescue tool are connected via special hose lines that also prevent power

arcing.

4.5 Hose lines

Connecting the equipment

5.

5.1 General points

The tool is equipped with two hose lines; they are connected to the pump unit via two hoses.

All hose assemblies are marked with a colour and have couplings to enable unmistakable

connection.

REMARK:

The devices can be equipped with different coupling systems.

They differ only by the article number and not by the designation.

Of course the coupling systems can also be reequipped at a later time.

WARNING / CAUTION!

To protect from electrical power arcing, the coupling parts must be always be

enclosed inside an appropriate LUKAS protection box before starting the rescue

work!!

Advertising