Opening the tool ( ):

Turn the star grip in a clockwise direction (in the direction of the

relevant symbol) and keep in this position.

Closing the tool ( ):

Turn the star grip in an counterclockwise direction (in the

direction of the relevant symbol) and keep in this position.

“Dead-man’s” function:

Following release, the star grip automatically returns to the

central position, guaranteeing the full load-holding.

6.1 Preparatory actions

Operation

6.

6.1.1 Initial commissioning

Before commissioning and following repairs, the equipment must be deaerated.

- Connect the equipment to the hydraulic pump (see chapter “Connecting the equipment”).

- Open / close the blade arms of the equipment without any load at least twice (see

chapter “Operation of the star grip”).

REMARK:

We recommend that during the deaeration, the attached aggregate for the hydraulic

supply should stand on a higher level than the body of the rescue tool.

Recommended procedure for the deaeration of the rescue tool:

1.) Fully open and close the tool once with the blade arms pointing upwards.

2.) Fully open and close the tool once with the blade arms facing downwards.

3.) Fully open and close the tool once with the blade arms pointing upwards.

4.) Fully open and close the tool once with the blade arms facing downwards.

6.1.2 Checking the pump unit

See separate operating instructions for the relevant unit

(or the hand pump).

REMARK:

Before each start-up of the hydraulic unit you have to make sure that the actuating

valves are set to depressurized circulation.

REMARK:

Before coupling the quick-disconnect couplings, the actuating valves of the

hydraulic unit are set to depressurized circulation.

If you use mono-couplings, you can also couple when the hoses are pressurized!

6.2 Operating the star grip (Item 1 on cover sheet)

Advertising
This manual is related to the following products: