8. Operation

Operating Procedures

This chap ter ex plains how to start and run an

RT

that has ei ther a gas o line or die sel en gine. Start ing
a gas o line en gine that is set up to burn LP-only or
dual-fuel is also dis cussed in this chap ter. Read
and un der stand all the pre vi ous chap ters be fore
you be gin to operate an

RT

Control Stations

An

RT can be started and op er ated from the

ground con trol box or from the plat form con trol box.

The ground control box can override the
platform control box at any time. If a person
operating the machine from the platform
becomes incapacitated, a person on the
ground can always take over machine
control.

The

RT is not Electrically insulated.

Death or Serious Injury to operating
personnel, can occur if the machine should
come into contact with energized electrical
wires during operation.

DO NOT attempt to operate the

RT ground

controls if the platform, scissor assembly or
any other conducting part of an

RT is in

contact with energized electrical wires or if
there is an immediate danger of such
contact.

NOTE

See the Electrical Hazard section, in this manual
for a complete explanation of the hazards
concerning electricity.

Emergency Stopping

To stop an

RT, push ei ther Emer gency Stop

switch, at any time on ei ther the ground con trol box
or the plat form con trol box and the en tire ma chine
stops and noth ing moves.

Figure 8.1 - Emergency Stop Switch at

Ground Control Box

Ground con trol box Emer gency Stop switch lo ca -
tion.

Figure 8.2 - Emergency Stop Switch at

Platform Control Box

Plat form con trol box Emer gency Stop switch lo ca -
tion.

NOTE

For a complete discussion of the Emergency
Stop switches, see , Controls chapter , and
Emergency Operation chapter 1, in this manual.

Operation Considerations

To use this chap ter, first de cide whether you will be
start ing and op er at ing the

RT from the ground con -

trol box or the plat form con trol box.

Be gin at the sec tion en ti tled Op er at ing From The
Ground con trol Box if you in tend to start and run the

RT from the ground con trol box.

Be gin at the sec tion en ti tled Op er at ing From The
Plat form Con trol Box if you in tend to start and run
the

RT from the plat form.

SR3370 & SR2770 – 13184A

Rev A

page 8 - 1

IMPORTANT

DANGER