Operator's troubleshooting, Troubleshooting 13-1, Operator troubleshooting chart 13-1 – Snorkel X33BE-sn10131+V-1 User Manual

Page 74: Troubleshooting, 13-1, 13-2, All systems sluggish, 13-1, Engine will not start, 13-1, Operator troubleshooting chart, 13-1, Sr will not drive, 13-1, Troubleshooting -1, Operator troubleshooting chart -1

Advertising
background image

13. Operator's Troubleshooting

Troubleshooting

All of the ac tions de scribed in this chap ter may be
per formed by an

RT op er a tor, a trained and qual i -

fied ser vice tech ni cian is not required.

The first col umn, of the fol low ing chart, lists some
com mon prob lems en coun tered by

RT op er a tors.

The sec ond col umn lists some of the causes for
each prob lem. The third col umn lists rem e dies.

Any problem that cannot be fixed by actions
listed below should be referred to a trained
and qualified

RT service technician.

SR3370 & SR2770 – 13184A

Rev A

page 13 - 1

Problem

Cause

Remedy

Engine will not start.

Battery switch set to off.

Turn battery switch to on.

Emergency Stop
switch(es) not on.

Set the ground control Emergency Stop
switch to on (up). Also, if you are trying to
start at the platform control box you
should pull the Emergency Stop switch, at
the platform control box, until it pops out
(on).

Key switch set to off.

Set the Key switch to on (the bar symbol).

Ground/Platform Selector
switch set to wrong
location.

If you are trying to start from the ground
control box, set the Ground/Platform
selector to ground (down). If you are trying
to start from the platform, set the selector
to platform (up).

Circuit Breaker tripped.

Push the circuit breaker in.

Fuel switch not set
correctly.

If you are trying to start a dual-fuel engine
be sure the fuel switch is set to the correct
fuel.

Out of fuel.

DANGER:
Keep flames and lit tobacco away from
open fuel tanks.

Remove the cap from the gasoline or
diesel tank to see if there is fuel.

Check the gauge(s) on top of the LP
tank(s). If you are using LP gas, be sure
the valve on top of the tank is open.

Clogged air filter.

Visually check the air filter gauge.

Engine oil too thick for
ambient temperature.

Check engine oil chart in “Specifications”
chapter 3 for correct oil weight.

Stabilisers inoperative

Platform not completely
down.

Completely lower the platform.

All systems sluggish.

Hydraulic oil is too thick.

Check for correct grade of Hydraulic Oil.

Allow time for machine to warm up.

RT will not drive
forward or reverse.

Free-wheeling valve is
open.

Close the free-wheeling valve.

Operator Troubleshooting Chart

CAUTION

Advertising
This manual is related to the following products: