Options, Bi-energy option 11-1, Dc motor 11-1 – Snorkel X33BE-sn10131+V-1 User Manual

Page 66: Dc motor operation 11-1, Master battery isolater switches 11-1, Bi-en ergy option -1

Advertising
background image

11. Options

This chap ter lists and ex plains the op tions avail -
able for an

RT.

Bi-En ergy Option

This con sists of a com bi na tion of both a die sel en -
gine and a 24V DC mo tor to give a Bi-En ergy op -
tion.

Spe cif i cally, a 24V DC mo tor is mounted in the con -
trol cab i net. This pro vides an al ter na tive power
source to the die sel en gine.

The DC mo tor is pow ered by four "Deep Cy cle
Trac tion Bat ter ies" and has an au to matic bat tery
charger that is mounted in the con trol cab i net.

DC motor

The DC mo tor lo cated in the con trol cab i net (see
Fig ure 11.1)

Figure 11.1 - DC Motor

DC motor operation

A Die sel / Elec tric switch, on the lower con trol box
(see Fig ure 11.2) is used to se lect ei ther the die sel
en gine or the DC mo tor.

If the die sel en gine [SWITCH UP] is se lected the
DC mo tor will not func tion and if the DC mo tor
(Elec tric) [SWITCH DOWN] is se lected the die sel
en gine will not run.

Figure 11.2 - Diesel/Electric Selection Switch

Af

ter se

lect

ing the DC mode, turn the ig

ni

tion

switch to the ON po si tion (the sec ond po si tion of
the switch) at the ground con trol box (see Fig ure
11.3)

Figure 11.3 - Start Switch, Ground

When en ter ing the plat form turn the ig ni tion switch
to the ON po

si

tion (the sec

ond po

si

tion of the

switch) at the plat

form con

trol box (see Fig

ure

11.4).

Figure 11.4 - Start Switch, Platform

Once the DC mode is se lected the mo tor will then
power all of the func tions in clud ing the sta bi lis ers in
the nor mal man ner. The only dif fer ence is that the
DC mo tor will only "run" when a func tion is se lected
e.g. rais ing the stack.

Master battery isolater switches

There are two Mas ter Bat

tery Iso la tor Switches

mounted at the end of the con trol cab i net (see Fig -
ure 11.5).

When the ma chine is not be ing used and is stowed
both of these bat tery iso la tor switches should be
turned to the "Off" po si tion.

When op er at ing with the die sel mo tor the 24V DC
bat tery iso la tor switch should be turned to the "Off"
po si tion.

When op er at ing the 24V DC mo tor the Die sel bat -
tery iso la tor switch should be turned to the "Off" po -
si tion.

SR3370 & SR2770 – 13184A

Rev A

page 11 - 1