Safety rules, Electrocution hazards, Tip-over hazards – Snorkel X52RT-sn10000+ User Manual
Page 7

OPERATOR’S MANUAL with Maintenance Information
Safety Rules
2
Electrocution Hazards
This machine is not electrically insulated and
will not provide protection from contact with or
proximity to electrical current.
Maintain safe distances from electrical power
lines and apparatus in accordance with
applicable governmental regulations and the
following chart.
Voltage
Phase to Phase
Minimum Safe
Approach Distance
Meters
0 to 300V
Avoid Contact
300V to 50KV
3.05
50KV to 200KV
4.60
200KV to 350KV
6.10
350KV to 500KV
7.62
500KV to 750KV
10.67
750KV to 1000KV
13.72
Allow for platform movement, electrical line
sway or sag and beware of strong or gusty
winds.
Keep away from the machine if it contacts
energized power lines. Personnel on the ground
or in the platform must not touch or operate the
machine until energized power lines are shut
off.
Do not operate the machine during lightning or
storms.
Do not use the machine as a ground for
welding.
Tip-over Hazards
Occupants, equipment and materials must not
exceed the maximum platform capacity.
Maximum capacity –
X43RT
Maximum occupants 7
Models with one extension deck
Platform retracted 680 kg
Only platform 454 kg
Only extension deck 227 kg
Only
Only platform
Extension
deck
454kg
227kg
Models with one extension deck
Platform retracted 680 kg
Platform with one extension deck 454 kg
Platform with one extension deck 227kg
For each extension deck 227 kg
Only Only
Extension Only platform Extension
deck deck
227kg 227kg 227kg
Maximum capacity –
X52RT
Maximum occupants 6
Models with one extension deck
Platform retracted 680 kg
Only platform 454 kg
Only extension deck 227 kg
Only
Only platform
Extension
deck
454kg
227kg