Safety rules, Electrocution hazards, Tip-over hazards – Snorkel X52RT-sn10000+ User Manual

Page 7

Advertising
background image

OPERATOR’S MANUAL with Maintenance Information

Safety Rules

2

Electrocution Hazards

This machine is not electrically insulated and
will not provide protection from contact with or
proximity to electrical current.

Maintain safe distances from electrical power
lines and apparatus in accordance with
applicable governmental regulations and the
following chart.

Voltage
Phase to Phase

Minimum Safe

Approach Distance

Meters

0 to 300V

Avoid Contact

300V to 50KV

3.05

50KV to 200KV

4.60

200KV to 350KV

6.10

350KV to 500KV

7.62

500KV to 750KV

10.67

750KV to 1000KV

13.72

Allow for platform movement, electrical line
sway or sag and beware of strong or gusty
winds.

Keep away from the machine if it contacts
energized power lines. Personnel on the ground
or in the platform must not touch or operate the
machine until energized power lines are shut
off.

Do not operate the machine during lightning or
storms.

Do not use the machine as a ground for
welding.

Tip-over Hazards

Occupants, equipment and materials must not
exceed the maximum platform capacity.

Maximum capacity –

X43RT

Maximum occupants 7

Models with one extension deck

Platform retracted 680 kg

Only platform 454 kg

Only extension deck 227 kg

Only

Only platform

Extension
deck

454kg

227kg

Models with one extension deck

Platform retracted 680 kg

Platform with one extension deck 454 kg

Platform with one extension deck 227kg

For each extension deck 227 kg

Only Only
Extension Only platform Extension
deck deck

227kg 227kg 227kg

Maximum capacity –

X52RT

Maximum occupants 6

Models with one extension deck

Platform retracted 680 kg

Only platform 454 kg

Only extension deck 227 kg

Only

Only platform

Extension
deck

454kg

227kg

Advertising