Chapter 7 – Prestart Inspection

TB60/66J – 0084030EE

29

Figure 7.7 – Fluid Level Indicator

A

Caution

Not all hydraulic fluid is suitable to use in the hy-

draulic system. Some have poor lubricating char-

acteristics and can increase component wear. Only

use hydraulic fluid as recommended.

If necessary, remove the filler cap and add fluid of the

proper type. Refer to Chapter 2 for the proper type and

grade of hydraulic fluid to use. The need to regularly add

fluid indicates a leak that should be corrected.

The sight glass on the reservoir has an internal thermom-

eter to measure the fluid temperature. The temperature

should be less than 93°C (200°F).

Fluid Filter

Checking the condition of the hydraulic fluid filter is part

of the machine maintenance schedule and should not

be performed by the operator.

Hoses, Tubes, and Fittings

Inspect all hydraulic hoses, tubes, and fittings for wear,

leakage, or damage (refer to Figure 7.8). Make sure the

hoses are properly routed to avoid sharp edges, kinking,

and scuffing. Inspect the tubes for dents or other dam-

age that may restrict fluid flow. Make sure all hoses and

tubes are held firmly in their support brackets.

Figure 7.8 – Hoses, Tubes, and Fittings

Include the emergency power battery when inspecting

and servicing the electrical system.

Battery Fluid Level

Remove the caps from each battery (refer to Figure 7.6).

Visually check the battery fluid level. If the level is not

within 6 mm (



/

4

) of the bottom of the filler neck inside

each hole, add distilled water.

Replace the caps on the batteries. The caps must be in

place and tight during machine operation.

Battery Terminals

Check the top of the batteries, the terminals, and cable

ends (refer to Figure 7.6). They should be clean and free

of corrosion. Clean the top of the batteries if necessary.

Clean the terminals and cable ends with a wire brush or

terminal cleaning tool. All cable ends must be securely

fastened to the terminals.

Cables and Wiring Harness

Inspect all cables and wiring for wear and/or physical

damage such as loose connections, broken wires, and

frayed insulation. Check the wiring in areas where a

change in routing direction may cause them to become

pinched. Make sure the cables and wires are properly

routed to avoid sharp edges, pinching, and scuffing.

Hydraulic System

Hydraulic power is supplied from an engine driven vari-

able displacement piston pump.

A

Danger

Hydraulic fluid escaping under pressure can have

enough force to inject fluid into the flesh. Serious

infection or reaction will result if medical treatment

is not given immediately. In case of injury by escap-

ing hydraulic fluid, seek medical attention at once.

The hydraulic reservoir is behind the door on the left side

of the turntable. The pump is mounted on the engine.

Fluid Level

Check the hydraulic reservoir fluid level with the aerial

platform stowed on a level surface. The fluid level must

be between the full and add marks as viewed on the

sight glass (refer to Figure 7.7).

Fluid Level and

Temperature Gauge