Danger, Caution – Snorkel TB66J CE User Manual

Page 47

Advertising
background image

Chapter 8 – Operation

TB60/66J – 0084030EE

43

If the platform overload sensing system is tripped while

operating the machine or if the system is in error mode

and can not be reset, the emergency power system

may still be used for emergency machine operation from

either the lower or upper controls.

A

Danger

The aerial platform can tip over if it becomes un-

stable. Death or serious injury will result from a

tip-over accident. Do not exceed the capacity values

indicated on the platform rating placard.

The overload sensing system is not active when the

machine is being driven with the booms in the stowed

position. This allows the machine to be driven without

the system sensing an overload due to rough ground

conditions.

To eliminate repeated tripping of the system during ma-

chine operation, there is a five second delay in machine

functions following:

• starting the engine.

• placing the drive/boom selector switch in the boom

position when the main boom is below horizontal

and fully retracted.

• removing excess load from the platform.

Four Wheel Drive

The machine may be equipped with a four wheel drive

system. This system operates full time and requires no

action by the operator.

Four wheel drive machines have a “4x4” decal on each

side of the chassis and all four of the wheel hubs are

drive hubs and look the same.

AC Generator

The optional generator supplies power to the electrical

outlet only when the engine is running and the machine

is stationary. The machine functions will not operate

when the machine/generator selector switch is in the

generator position.

A

Caution

Cold hydraulic oil does not flow well and may pro-

duce improper generator output voltage. Improper

outlet voltage can damage some electrical power

tools and equipment. Warm the hydraulic oil before

operating the generator.

Do not operate the generator unless the hydraulic oil

temperature is at least 38°C (00°F). Refer to Cold

Weather Start-Up for a hydraulic oil warm-up proce-

dure.

Figure 8.5 – Upper Controls

If the platform becomes significantly overloaded, or if

an upward force on the platform exceeds approximately

445 N (00 lb), the system will enter into error mode,

stopping all functions from the upper and lower controls.

The horn will then sound constantly and the overload

light will stay illuminated at the upper and lower controls

(refer to Figures 8.5 and 8.6).

Figure 8.6 – Lower Control Panel

The system will remain in error mode until the excess

load is removed from the platform and the emergency

stop button or start switch is cycled off and back on,

resetting the system. At that time, the machine functions

are operational.

A

Caution

The emergency power system is for emergency

lowering and stowing only. The length of time the

pump can be operated depends on the capacity

of the battery. Do not use this system for normal

operation.

Engine

Temperature

Gauge

Platform

Overload Light

Platform

Overload Light

Advertising
This manual is related to the following products: