Baldor Series 5 Inverter IP-65 User Manual

Page 10

Advertising
background image

8

fault). To set the control to automatically reset after a
fault has been cleared, set Jumper J3 to the "AUTO"
position. See Figure 12. (Also see section VIB, on page
9 and Table 4, on page 10.)

WARNING! The motor will automatically
restart when the AC line is applied, if Jumper

J4 is set to the "AUTO" or “MAN” position and the
Start/Stop Switch is eliminated with a jumper
installed between the RUN and COM terminals.

D. Motor Frequency Selection (J5)

– Jumper J5 is facto-

ry set to the “60Hz” position, for 60 Hz motors. For 50
Hz motors, set Jumper J5 to the “50Hz” position. See
Figure 13.

E. Motor Frequency Multiplier Selection (J6)

– Jumper

J6 is factory set to the “1X” position, for motor frequency
corresponding to the frequency setting of Jumper J5 (50
or 60 Hz). To double the output frequency to the motor,
set Jumper J6 to the “2X” position (100 or 120 Hz). See
Figure 14.

Note:

When doubling the motor frequency, the motor

will produce full torque up to its base speed. The torque
will be linearly reduced to 50% at the maximum doubled
frequency.

F. Boost Mode Selection (J7):

Jumper J7 is factory set to

the "FIX" position, for fixed boost voltage. For adjustable
boost voltage, using the BOOST trimpot, set Jumper J7
to the "ADJ" position. See Figure 15. (See section
VIIIG, on page 12).

IV.

MOUNTING INSTRUCTIONS

WARNING! This motor control is not designed to
be used in an explosion-proof application.

It is recommended that the control be mounted vertically on
a flat surface with adequate ventilation. Leave enough room
below the control to allow for AC line, motor connections and
any other wiring. Although the control is designed for outdoor
and wash down use, care should be taken to avoid extreme
hazardous locations where physical damage can occur. If
the control is mounted in a closed, unventilated location,
allow enough room for proper heat dissipation. If operating
the control at full rating, a minimum enclosure size of 12”W X
24”H X 12”D is required. See Figure 3, on page 4.

V.

RECOMMENDED HIGH VOLTAGE DIELECTRIC
WITHSTAND TESTING (HI-POT)

Testing agencies such as UL, CSA, VDE, etc., usually require that equipment undergo a hi-
pot test. In order to prevent catastrophic damage to the speed control, which has been
installed in the equipment, it is recommended that the following procedure be followed.
Figure 16, on page 9 shows a typical hi-pot test setup.

Note: All equipment AC line inputs must be disconnected from the AC power.

A.

Connect all equipment AC power input lines together and connect them to the H.V. lead
of the hi-pot tester. Connect the RETURN lead of the hi-pot tester to the frame on which
the control and other auxiliary equipment are mounted.

!

FIGURE 12 – RESTART

MODE SELECTION

FIGURE 13 – MOTOR

FREQUENCY SELECTION

J5 Set for

60 Hz Motors

(Factory Setting)

J5 Set for

50 Hz Motors

J5

60 Hz

50 Hz

FREQ

J5

60 Hz

50 Hz

FREQ

FIGURE 14

MOTOR FREQUENCY

MULTIPLIER SELECTION

!

FIGURE 15

BOOST MODE SELECTION

J4 Set for Auto

Reset Mode

J4 Set for Manual

Reset Mode

(Factory Setting)

J4

AUTO

MAN

J4

AUTO

MAN

J6 Set for 1X

Motor Frequency

(Factory Setting)

J6 Set for 2x

Motor Frequency

J6

1X

2X

MULT

J6

1X

2X

MULT

J7 Set for

Adjustable Boost

J7 Set for

Fixed Boost

(Factory Setting)

J7

FIX

ADJ

BOOST

J7

FIX

ADJ

BOOST